#soda-fountain #cleaning #sanitizing #maintenance
# Overview
Step-by-step cleaning, sanitizing and upkeep for the home Diet Coke fountain. The system is a Diet Coke bag-in-box (BIB) feeding a Flojet N5000 pump, which pushes syrup through one circuit of a cold plate. A McCann's Big Mac carbonator, fed through a water filter and backflow preventer, pushes soda water through a second circuit. The cold plate sits in a lidded bath in the mini fridge, and both circuits end at a single post-mix valve. See [[Home Soda Fountain Chilling]] for why the system is built this way.
Commercial schedules (Coca-Cola, Lancer, Cornelius) assume a restaurant pouring all day. Here the risk is the opposite: low volume, so syrup and water sit in the lines. Anything marked *(home adaptation)* or *(inference)* is scaled down from commercial practice and is not a manufacturer spec. Everything else is attributed to its source in parentheses and linked under References.
**One rule above all:** this system uses **one sanitizer chemistry, chlorine** (Kay-5 packets, or measured plain bleach for line sanitizing), with a plain-water flush between every chemical step. Never let chlorine meet an acid sanitizer (Star San, Saniclean, vinegar, descalers) or ammonia, because both make toxic gas. Keep caustic cleaners off the aluminum cold plate.
# Schedule
| When | Task | Time | Procedure |
|---|---|---|---|
| Every pour after ≥30 min idle | Pour off the first few oz | 10 s | [[#First pour]] |
| Weekly | Brush and sanitize nozzle and diffuser, soak BIB connector, wipe valve, wash drip tray | 15 min | [[#Nozzle, diffuser and connector]] |
| Weekly | Look at the bath: level, clarity, smell, lid seated | 1 min | [[#Bath checks]] |
| Monthly | CO2 leak check, backflow vent check, 40°F temperature test | 15 min | [[#Monthly checks]] |
| Every **90 days** max, and at each BIB change | Full syrup-line clean and sanitize | 45 min | [[#Syrup line clean and sanitize]] |
| Quarterly | Glycol bath: concentration and pH. Vacuum fridge condenser | 10 min | [[#Bath checks]] |
| Every 6 months | Replace water filter cartridge and flush it | 20 min | [[#Water filter change]] |
| Yearly | Drain and refill bath, deep-clean the syrup circuit while the plate is warm, carbonator inspection | 2–3 h | [[#Annual service]] |
| Before and after trips | Shut down and restart | 10 min | [[#Idle periods and vacations]] |
Sources for the intervals:
- **90-day line sanitize:** Cornelius ("Sanitizing Post-Mix Syrup Systems … every 90-days"). Adding a full sanitize at every BIB change is a *(home adaptation)*.
- **Weekly connector soak:** Coca-Cola soaks connectors weekly and at every BIB change.
- **Nozzle care:** Coca-Cola says daily. Lancer says clean daily and sanitize "bi-weekly." Weekly is a *(home adaptation)* for a few drinks a day.
- **Filter:** Coca-Cola says a cartridge is "usually required every six months." Everpure's cartridge sheet says replace "at least once a year."
- **Annual bath change:** Lancer drains its water baths yearly. KegLand and Micro Matic replace glycol yearly.
# Resources
Supplies, with prices captured 2026-10-11:
| Item | Use | Price / source |
|---|---|---|
| Kay-5 sanitizer packets | Default sanitizer, and the **only** one for nozzles (Coca-Cola says no bleach on nozzles). 1 packet in 2.5 gal = 100 ppm | \$59.85 for 50 (BUNN 24634.0001, WebstaurantStore). ==That listing doesn't state ppm; verify with a strip== |
| Plain unscented bleach | Optional line sanitizer only, dosed by the table below | Grocery |
| Chlorine test strips, 10–200 ppm | Verify every sanitizer batch | \$3.88 per 100 (RestaurantSupply) |
| Unscented dish detergent | Routine line cleaner (Cornelius) | Grocery |
| BLC Beverage Line Cleaner (potassium hydroxide) | Annual deep clean and flavor removal only | \$23.99 per 32 oz (Adventures in Homebrewing) |
| pH strips | Confirm caustic is fully rinsed; check glycol pH | ==Not priced== |
| BIB cleaning adapter for the red Coke screw-on connector, Lancer 15C07145 | Lets the pump pull from a bucket. A bag valve cut from an empty BIB also works (Cornelius, Lancer) | \$9.69 (Howdy Brewer) |
| Short length of 3/8" ID food-grade tubing | Adapter-to-bucket pickup tube | On hand |
| Lancer 22-0017 nozzle brush | Nozzle and diffuser channels. Replace about every 90 days | \$13.99 (Howdy Brewer) |
| NSF-H1 **silicone** O-ring grease | Valve O-rings. Cornelius specifies Dow 111 silicone and never petroleum jelly. Avoid mineral-oil lubes such as Lubri-Film, which can swell EPDM | ==Not priced; confirm silicone base== |
| Two or three dedicated 2–3 gal buckets | Water, cleaner, sanitizer. Never used for anything else | On hand |
| Thermometer you can check at 32°F | Temperature test | On hand |
| Everpure 4CB5-S cartridge | Water filter | \$112.99 (Howdy Brewer) |
| Inhibited food-grade propylene glycol | Bath refill, if running glycol | \$52.99 per gal (CellarScience, MoreBeer) |
| Refractometer with a PG scale | Glycol concentration. Automotive testers misread PG (Micro Matic) | ==Not priced== |
| Low-mounted CO2 detector | Safety | ==Not priced== |
| Safety glasses, nitrile gloves | Chemicals and pressurized parts | On hand |
# Configuration
## Operating settings
| Setting | Value | Source |
|---|---|---|
| Carbonator CO2 | 100 psi normal, 120 max. Drop to 80–90 if drinks foam | McCann's 17-0500 (Coca-Cola uses 105 for standalone units) |
| Water to carbonator | 40–60 psi preferred, 70 max | McCann's 17-0500 |
| Flojet BIB pump CO2 | 65 psi on its **own** regulator, never above 80 | Flojet N5000 IOM, Coca-Cola |
| Bath setpoint | 33–34°F, low-temperature alarm about 31°F | [[Home Soda Fountain Chilling]] |
| Drink at the valve | ≤40°F, no ice, stirred 15 s | Coca-Cola |
| Anything pushed through the pump | ≤110°F | Flojet rates the N5000 at 34–120°F. The 110°F cap keeps a margin *(inference)* |
## Solution mixes
| Solution | Mix | Contact | Notes |
|---|---|---|---|
| Line cleaner (routine) | **1 Tbsp (0.5 oz) unscented dish detergent per gal**, at 100–110°F | 10–15 min hold *(home adaptation)* | Cornelius specifies the dose at 70–100°F but gives no hold time. Slightly warmer offsets the cold plate |
| Sanitizer, Kay-5 | **1 packet per 2.5 gal** = 100 ppm. **Mix fresh each day you use it** | Label: 1–2 min. Cornelius line hold: 10–15 min max. Coca-Cola nozzle soak: ≥3 min | Kay-5 label |
| Sanitizer, 7.5% bleach (current Clorox), lines only | **1–1.5 tsp per gal ≈ 100–150 ppm**. Aim mid-range | Same as Kay-5 | Calculated, so **check with a strip**. Never exceed 200 ppm (Cornelius, Clorox). A 10–200 ppm strip can't tell 200 from 290, so don't dose near the top. Cornelius's "0.5 oz per gal" assumes old 5.25% bleach and gives ~290 ppm with 7.5% |
| Deep cleaner, BLC | **2 oz (4 Tbsp) per gal**, 80–110°F | 20 min static | BLC label dose. Brewers Association caustic spec: 2–3%, 80–110°F, ≥20 min static, rinse until pH is neutral. **Keep off the aluminum** |
| Glycol bath | **30% inhibited PG in distilled water**: 0.75 gal PG + 1.75 gal water for 2.5 gal; 0.9 + 2.1 for 3 gal | — | Dow: below 25% risks bacterial growth; keep pH 8–10 |
Chlorine stays effective cold: at 25–200 ppm it killed as well at 36°F as at 77°F (Tuncan 1993). Detergent and caustic don't, which is why cleaner goes in warm and gets refreshed during the hold, and why the deep clean is done while the plate is out of the bath *(inference)*.
# Procedures
## Depressurize sequence
Use this before any work on the water side, the carbonator or the cold plate lines. It combines the McCann's, Manitowoc and Lancer steps; the order is an *(inference)*.
1. **Put on safety glasses.**
2. Unplug the carbonator.
3. Close the water shutoff to the carbonator, then close its CO2.
4. Open the valve into a pitcher until it sputters, or lift the McCann's relief-valve toggle until the hissing stops.
5. **If the syrup side is involved too:** close the Flojet's CO2 supply, then open the valve to relieve syrup pressure (Flojet service sheet).
## First pour
1. If the valve hasn't been used in 30+ minutes, pour off a few ounces to clear the warm line in the tower. Coca-Cola discards a full 20 oz before a temperature test. A few ounces is enough for everyday drinks *(home adaptation)*.
2. Wipe the nozzle tip and splash area with a clean damp cloth if there's visible syrup.
## Nozzle, diffuser and connector
Weekly. Steps are written for a **Lancer LEV**, the most common single valve. ==Confirm the valve model==: a Cornelius UF-1 has a lift-off front cover, and Cornelius says not to soak valve components in chlorine, so soak only the nozzle and diffuser, briefly.
1. Mix a fresh **Kay-5** batch: 1 packet in 2.5 gal of lukewarm water, about \$1.20. Strip-check it at about 100 ppm. Coca-Cola says no bleach on nozzles.
2. Turn off power to the valve (unplug the tower or switch the valve off) so it can't fire.
3. **Remove the nozzle:** twist it counterclockwise and pull it down. **Remove the diffuser:** pull it straight down (Lancer).
4. Rinse both under **warm, not hot** water to soften dried syrup. Coca-Cola says no hot water and no dishwasher.
5. Scrub the inside channels with the nozzle brush.
6. Soak both in sanitizer for **at least 3 minutes** (Coca-Cola). Lancer's soak is 15 minutes. Never overnight (Coca-Cola).
7. Brush or wipe the underside of the valve body with a cloth dipped in sanitizer. Don't soak the valve body.
8. Let the parts air dry on a clean surface.
9. Check the O-ring above the diffuser. A damaged or misseated O-ring causes water leaking around the nozzle (Lancer). If it's dry, lightly coat it with silicone grease.
10. Reinstall the diffuser, then the nozzle (twist clockwise). Restore power.
11. **Connector:** unscrew the red connector from the BIB. Soak it in the sanitizer for **1 minute**, shake it off, and screw it back on until it is fully engaged (Coca-Cola).
12. Pour and discard a short drink, then taste. Leftover cleaning solution causes foam and off-taste (Lancer).
13. Empty, wash and dry the drip tray. Use the leftover sanitizer for wiping today only, then pour it down a sanitary drain.
## Bath checks
**Weekly look (both bath types):**
- The plate is fully submerged, the lid is seated, and the foam seals at the tube notches are intact.
- The bath is clear, with no film, slime or smell.
- No brass or copper has ended up below the fluid line. Trace copper corrodes aluminum (SUEZ).
**Plain distilled-water bath:**
- Change it whenever it turns cloudy, filmy or smelly. Expect about monthly at first *(home adaptation)*. Optionally add 1–2 Tbsp of 3% hydrogen peroxide per gallon after each refill *(unsourced suggestion)*.
- Never add bleach. Chloride left behind pits aluminum.
**Glycol bath (quarterly):**
1. Check concentration with the PG refractometer. Target about 30%; Lancer checks its glycol monthly. Top up with premixed 30%, not plain water.
2. Check pH with a strip. Target 8–10; **replace the bath if pH is below 7**, or if it is dark or sludgy (Dow).
3. Never add peroxide or bleach to glycol. Oxidizers use up the inhibitor *(inference)*.
4. Confirm the Inkbird low-temperature alarm still trips. Glycol removes the 32°F floor, so a stuck relay could freeze the product circuits.
**Quarterly, either bath:** vacuum the mini fridge's condenser coils so it keeps its pull-down capacity. Coca-Cola does dispenser condensers monthly.
## Monthly checks
1. **CO2 leak check:** with the system idle, close the cylinder valve and watch the high-pressure gauge for 15+ minutes. A steady drop means a leak (Coca-Cola). Find it with soapy water on fittings, regulators, the carbonator and pump. Reopen the valve **fully** afterwards; Coca-Cola says a partly open valve leaks around the stem. Change an unmarked cylinder when it reads under 500 psi.
2. **Backflow vent:** look at the ASSE 1022 dual-check vent. It should be dry. If it drips or is plugged, **stop using the fountain and replace the device** (Minnesota Dept. of Health). Never plug the vent.
3. **Temperature test** (Coca-Cola):
1. Put the thermometer in a cup of ice water. It should read exactly 32°F; adjust it if not.
2. Pour off 20 oz if the valve has been idle for 30+ minutes.
3. Draw a cup with no ice and stir it with the thermometer for 15 seconds.
4. The reading must be **40°F or lower**.
4. **Taste test:** pull plain soda water alone (close the syrup stem, or use a soda lever if the valve has one) and taste it, then taste a full drink. That tells you whether an off-note is on the water side or the syrup side.
## Syrup line clean and sanitize
Every 90 days at most (Cornelius), and at each BIB change *(home adaptation)*. This uses the Flojet pump itself to pull solutions from a bucket, which is the Cornelius/Lancer bucket method, so no hand pump is needed. The plate stays in its cold bath.
**Prep:**
- Three buckets:
- **Water:** ~1 gal of warm water.
- **Cleaner:** 1 gal at 100–110°F with 1 Tbsp dish detergent.
- **Sanitizer:** a fresh Kay-5 packet in 2.5 gal, or 7.5% bleach at 1–1.5 tsp/gal. Strip-test it: **100–150 ppm**.
- Fit the cleaning adapter (or a saved bag valve) with a pickup tube long enough to reach the bottom of a bucket.
- Safety glasses on. Keep acids and ammonia cleaners out of the area.
- If the valve's mounting block has shutoff stems, you can close the **soda-water** stem so only the syrup circuit runs. Otherwise let soda water run too; it does no harm *(inference)*.
**Steps:**
1. **Disconnect:** unscrew the red connector from the BIB (Coca-Cola). Screw it onto the cleaning adapter and drop the pickup tube into the **water** bucket.
2. **Water flush:** hold the valve open until clear water runs from the nozzle, then about 30 seconds more. The pump may pop or whistle while it pulls air; that's normal briefly.
3. **Detergent:** move the pickup to the **cleaner** bucket. Dispense until suds show at the nozzle.
4. Hold for **10–15 minutes**. Halfway through, dispense a few seconds to pull a fresh warm slug into the plate, since the cold plate chills the cleaner *(home adaptation)*.
5. **Rinse:** move the pickup back to **water** and flush until there are no suds and no soapy taste. Leftover detergent causes foam.
6. **Sanitize:** move the pickup to the **sanitizer** bucket and dispense until you smell chlorine at the nozzle. Hold for **10–15 minutes, no longer** (Cornelius's maximum). Limiting exposure also protects the pump's acetal body, which charts rate poorly against chlorine *(inference)*.
7. **During the hold:** with the valve switched off, do steps 3–10 of [[#Nozzle, diffuser and connector]] in the same sanitizer. **Reinstall the diffuser and nozzle before continuing.**
8. **Final flush:** move the pickup to fresh **water** and flush until there is no chlorine smell or taste. This follows Cornelius ("residual sanitizer can create a health hazard"). Lancer instead flushes with syrup only and no water rinse; the water rinse is the more conservative choice for taste.
9. **Connector:** unscrew the connector from the adapter. Soak it in sanitizer for **1 minute** and shake it off (Coca-Cola).
10. **Reconnect:** screw the connector onto the BIB (or the new box) until it is fully engaged. For a new box, open the flap by striking it with your palm, not a knife, and remove the dust cap (Coca-Cola).
11. **Purge:** dispense until full-strength syrup flows. Discard drinks until **two in a row taste right** (Servend).
12. **New BIB only:** check the Enjoy-By date (Coca-Cola uses 75-, 90- or 120-day dating). Optionally check the ratio with a ratio cup (Coca-Cola 5.0/5.5 dual cup, 05-1436).
13. Pour the leftover sanitizer down a sanitary drain, not a storm drain (Cornelius).
**If the pump won't restart on a new box:** the bag fitment isn't fully engaged, or the line is vacuum-locked. Remove the connector, press its valve in for 3–5 seconds, and reconnect (Flojet; Coca-Cola SERV-376).
## Water filter change
Every 6 months (Coca-Cola).
1. Run the [[#Depressurize sequence]] (steps 1–4).
2. Relieve pressure at the filter head. If the head has a built-in valve, lift its handle fully.
3. Push the cartridge up, turn it ¼ turn left, and pull it out.
4. Insert the new cartridge and turn it ¼ turn right. Turn the water back on.
5. **Flush the cartridge for 5 minutes.** This comes from Everpure's BW-4400 change sheet; ==check the sheet for your exact cartridge==. Run it to a drain through the head's flush valve if it has one. Otherwise disconnect the line before the carbonator and run it into a bucket.
6. Write the date on the cartridge.
7. Restart the carbonator with the [[#Carbonator restart]] sequence.
Connecticut municipal water is mostly soft (median about 53 mg/L), so the scale inhibitor in the cartridge is a bonus, not a necessity. Never feed the carbonator softened water, because it causes foaming (Lancer).
## Carbonator restart
McCann's 17-0500, used after any depressurize. Safety glasses on.
1. Open the relief valve: toggle lever **vertical**.
2. Turn on the water. Fill until water comes out of the relief valve's vent hole.
3. Close the relief valve: toggle lever **horizontal**.
4. Turn on CO2 and set it to **100 psi**.
5. Leak-check the water and CO2 fittings.
6. Plug in the carbonator. The motor won't start until a valve is opened.
7. Open the valve and let the motor **cycle several times** to flush the system.
If drinks come out flat or too sweet afterwards, the tank is probably air-locked. Pull the relief ring several times (Coca-Cola).
## Annual service
Do this once a year, combined with the bath change, because pulling the plate out warms it up and lets the cleaner work properly.
**Bath:**
1. Run the full [[#Depressurize sequence]], including step 5, so neither circuit is under pressure.
2. Unplug the mini fridge. Lift the cold plate out onto a towel-lined tray, leaving its lines connected and handling the fittings gently.
3. Drain the bath. Don't dump glycol in a storm drain; follow local disposal rules.
4. Wash the tub and the **outside** of the plate with mild dish detergent in about 100°F water, using a **nylon brush, never wire** (Cornelius). Rinse, then do a final rinse with distilled water.
- No caustic, PBW or bleach soaks on the aluminum.
5. Inspect the plate: pitting, white corrosion or green spots (copper) mean something in the bath is attacking it.
**Deep clean the syrup circuit while the plate is warm:**
1. Restore CO2 to the Flojet only, at 65 psi.
2. Do the [[#Syrup line clean and sanitize]] procedure, but use **BLC at 2 oz/gal, 80–110°F, held 20 minutes** instead of dish detergent.
3. Flush with water until **pH strips read neutral** (BLC; Brewers Association).
4. Then sanitize as normal.
5. Keep BLC off the aluminum. NIOSH lists aluminum as incompatible with sodium hydroxide, and caustic reacts with aluminum to give off flammable hydrogen. Rinse any drip off immediately.
**Refill and restart:**
1. Refill with 30% inhibited PG in distilled water (check it with the refractometer), or with plain distilled water.
2. Seat the plate on its plastic feet, close the lid, and plug the fridge back in.
3. Restart the carbonator with [[#Carbonator restart]].
4. **Wait for the bath to reach 33–34°F** before pouring. That can take hours.
**Carbonator and valve:**
1. With safety glasses on and the carbonator unplugged but still pressurized, lift the relief-valve toggle briefly to confirm it isn't stuck. If it keeps weeping afterwards, replace it (Lancer remedy) *(home adaptation)*.
2. Inspect the backflow device and the water inlet fittings.
3. Clean the pump's internal 100-micron strainer **only if** the motor has been running long or continuously. ==Access on the McCann's pump is unconfirmed==; on the equivalent Lancer pump it is behind a brass plug.
4. Replace the nozzle and diffuser O-rings if they're flattened or cracked. Replace the nozzle brush.
## Idle periods and vacations
All of this is *(home adaptation)* built from Coca-Cola, Servend and McCann's steps. No source gives an "idle N days" rule.
| Idle time | Do this |
|---|---|
| Hours | First-pour rule: discard a few oz |
| 3–14 days, left on | Remove and rinse the nozzle and diffuser. Discard a full cup, then taste. Run a full sanitize only if an off-taste doesn't clear after a minute of flushing |
| Vacation (1+ week) | **Shutdown:** unplug the carbonator, then close its water supply, then close the CO2 cylinder (this also stops the Flojet). Leave the bath running and the BIB connected. **Restart:** water on, CO2 on (check gauges), carbonator plugged in and cycled with several draws. Discard drinks until two taste right, then do the 40°F test |
| Months, or BIB past its Enjoy-By date | Treat as storage: full sanitize, purge liquids, restart with fresh syrup (Servend) |
Store spare BIBs at 40–77°F, arrow up and off the floor. **Never refrigerate them**, and keep them out of a hot garage, because diet syrup is especially heat-sensitive (Coca-Cola). A 2.5-gal box may fit home use better than a 5-gal: at about 3 drinks a day a 5-gal box lasts roughly 100+ days, which is about the length of the Enjoy-By window *(estimate)*.
# Decisions
- **Chlorine is the only sanitizer.**
- **Why:**
- It's what Coca-Cola, Lancer and Cornelius specify.
- It keeps working at cold-plate temperatures (Tuncan 1993).
- Strips make it easy to verify.
- Kay-5 for nozzles and connectors, because Coca-Cola rules out bleach there. Measured bleach is allowed only for line sanitizing.
- **Alternatives rejected:**
- **Star San:** acid, labeled not for soft metals, high-foaming in pumps, and makes chlorine gas if it meets chlorine.
- **Quats and iodophor:** lose efficacy cold at low ppm, and iodine is rated poorly on the pump's acetal body.
- **Hydrogen peroxide:** not a labeled line sanitizer.
- **Water flush after sanitizing.**
- **Why:** Cornelius's approach gives the best taste margin.
- **Alternative:** Lancer's syrup-only purge is valid at 200 ppm or below, but it relies on accurate dosing.
- **Dish detergent for routine cleaning, BLC once a year.**
- **Why:** detergent is gentle and needs no pH check. Caustic is saved for when the plate is out of the bath and warm.
# Troubleshooting
- **Off-taste:** do the isolation test (soda water alone vs. a full drink).
- **Chlorine taste in soda water:** the filter is expired, or sanitizer wasn't fully flushed (Coca-Cola).
- **Musty taste:** biofilm in the nozzle or syrup line. Clean and sanitize *(inference)*.
- **Sulfur smell:** usually the source water, especially well water. Check the water first *(inference)*.
- **Metallic taste:** look for copper or brass in contact with carbonated water. The McCann's brass pump is on the plain-water side by design. Stop using the fountain until it's found.
- **Foamy drinks:** over 40°F, dirty nozzle or diffuser, leftover detergent, or carbonator CO2 too high. McCann's says to drop to 80–90 psi.
- **Flat drinks:** CO2 low or empty, or the carbonator tank is air-locked. Pull the relief ring several times.
- **Weak drinks or soda water only:** empty BIB, connector not engaged, Flojet starved, or a syrup stem closed.
- **Too sweet:** carbonator CO2 low or empty, clogged filter, water pressure under 40 psi, or diffuser missing (Coca-Cola).
- **Pump pops or whistles:** empty BIB or an air leak in the suction line. If it keeps popping, **close the Flojet's CO2 supply first**, then disconnect the pump's CO2 line until it's fixed (Harvest Pure; Flojet). Never pull a live CO2 line, because it can vent continuously into the room.
- **Flavor lingers after cleaning:** diaphragms can hold flavor. A BLC deep clean usually fixes it. If not, a replacement Flojet T5000 pump runs \$59–75.
# TODO
- ==Confirm the valve brand/model (Lancer LEV vs. Cornelius). Nozzle removal and soak rules differ==
- ==Confirm the BIB connector is the red Coke screw-on before buying the Lancer 15C07145 adapter==
- ==Find where the McCann's pump strainer is and how to get to it==
- ==Buy supplies: Kay-5, chlorine strips, BIB adapter, nozzle brush, silicone O-ring grease, pH strips, CO2 detector==
- ==Once the system is running, add a `# Build Log` and record each line sanitize, filter change and bath change with its date==
# References
- [[Home Soda Fountain Chilling]]
- [Coca-Cola Valves of Gold brochure](https://www.cokesolutions.com/content/dam/cokesolutions/us/documents/foodservice-quality/foodservice-quality-ValvesOfGoldBrochure.pdf): nozzle care, connector soak, BIB change, regulator settings, temperature test, troubleshooting matrix, filter interval
- [Coca-Cola daily fountain cleaning crew guide](https://crewconnect.coca-cola.com/wp-content/uploads/2022/01/02-CA-daily-fountain-v2.pdf): "DO NOT USE HOT WATER or BLEACH" on nozzles
- [Coca-Cola Syrup Quality Guidelines](https://www.cokesolutions.com/content/dam/cokesolutions/us/documents/foodservice-quality/foodservice-quality-syrup-quality.pdf): BIB storage and Enjoy-By dating
- [Cornelius installation instructions (COR001)](https://www.cpsohio.com/media/import/manuals/COR/COR001.pdf): bucket method, detergent and bleach dilutions, 10–15 min maximum, water flush, cold plate washing
- [Cornelius Venture manual, sanitizing post-mix syrup systems](https://www.manualslib.com/manual/1968466/Cornelius-Venture.html?page=34): 90-day interval
- [Cornelius UF-1/UFB-1 training manual](https://www.manualslib.com/manual/31876/Cornelius-Post-Mix-Valves-Ufb-1.html): Dow 111 silicone lube, chlorine soak caution, ratio setting
- [Lancer LEV/LMV service manual](https://www.sodadispenserdepot.com/Documents/Lancer-LEV-LMV-100-145-Valve-Service-Manual.pdf) and [Lancer LEV installation guide](https://www.totalapex.com/amfile/file/download/file/13268/product/11611/): nozzle and diffuser removal, O-rings, ratio procedure
- [Lancer 1523 manual](https://manualmachine.com/lancer/1523/5982037-user-manual/): caustic and sanitizer procedure, 15-minute nozzle soak, syrup-only purge
- [Lancer R6000S manual](https://lancerbeverage.com/uploads/tools/008-R6000S-Superchiller-Manual-051110-1.pdf): annual bath drain, 30% glycol
- [McCann's carbonator and probe installation (17-0500)](https://www.multiplexbeverage.com/getmedia/eceb542f-0506-4c5c-8d6a-1bb5999caf2d/17-0500_Carbonator_and_Probe_inst_mcn_06022021.pdf) and [McCann's spec sheet](https://res.katom.com/products/055/055-E400397/055-E400397.pdf): pressures, start-up, relief valve, probe
- [Lancer Turbo-Carb manual](https://www.partstown.com/modelManual/LAN-CED-TURBO-CARB_spm.pdf): strainer and check-valve service on an equivalent carbonator
- [Flojet N5000 IOM](http://www.depcopump.com/datasheets/flojet/N5000-Series_IOM_Manual.pdf) and [Flojet N5000 service pump sheet](https://www.multiplexbeverage.com/getmedia/32e90295-97cf-4480-a19c-78d3806055be/bibpump_flojetn5000.pdf): pump ratings, troubleshooting, CO2 shutoff before service
- [Kay-5 EPA label 5389-15](https://www3.epa.gov/pesticides/chem_search/ppls/005389-00015-20120626.pdf): 100 ppm per 2.5 gal, fresh daily
- [Clorox 7.5% bleach sanitizing guide](https://prod-liv.mt.gov/_docs/ME/Egg/Clorox-Disinfecting-Bleach-7.5-percent-Guide-Shell-Egg.pdf) and [OSU Extension bleach guide](https://extension.okstate.edu/fact-sheets/guidelines-for-the-use-of-chlorine-bleach-as-a-sanitizer-in-food-processing-operations.html): 200 ppm ceiling, strips
- [Brewers Association draught line cleaning best practices](https://cdn.brewersassociation.org/wp-content/uploads/2019/01/DBQ2018-Draught_Line_leaning_Best_Practices.pdf): caustic strength, contact time, rinse to neutral
- [Tuncan 1993, J. Food Protection](https://agris.fao.org/search/en/records/65df39510f3e94b9e5d63cfe): sanitizer efficacy at cold temperatures
- [Dow DOWFROST engineering guide](https://www.blichmannengineering.com/media/wysiwyg/pdf/Dowfrost_Engineering_Guide.pdf): glycol concentration, pH, aluminum
- [Everpure BW-4400 cartridge change](https://cdn.shopify.com/s/files/1/0621/5994/5981/files/BW-4400.pdf): 5-minute flush, at-least-yearly change
- [Minnesota Dept. of Health backflow fact sheet](https://www.health.mn.gov/communities/environment/water/docs/factsheet/bevdisp.pdf): ASSE 1022 vent checks
- [Star San EPA label](https://www3.epa.gov/pesticides/chem_search/ppls/065001-00001-20050317.pdf), [Vanderbilt Poison Control](https://www.vumc.org/poison-control/node/773), [NIOSH sodium hydroxide](https://www.cdc.gov/niosh/npg/npgd0565.html): never-mix rules, caustic and aluminum
- [Missouri Division of Fire Safety, CO2 safety](https://dfs.dps.mo.gov/safetytips/carbondioxide.php): CO2 pooling and detectors
# Changelog
## 2026-10-11
- Note created from research into OEM cleaning procedures, chemical compatibility (Flojet, stainless, aluminum), component procedures and home adaptations
- Independent review pass:
- Added depressurize-first steps (annual plate lift, pump CO2 line) and eye protection first
- Switched nozzles to Kay-5 only
- Lowered the bleach target to 100–150 ppm
- Replaced the mineral-oil lube with silicone grease
- Fixed source attributions
- Prices captured 2026-10-11