#voron #voroncascade #cnc #electronics #wiring #flexihal #linuxcnc #ueb
# Overview
**Current revision: Rev O (2026-11-15)** — the revision letter is in the frontmatter, on every drawing's title block, and the [[#Changelog]] lists what each letter changed.
==**On hold: do not wire yet.**== Three independent reviews have looked at this design and none has passed it. By Erik's decision of 2026-11-15 the next step is the bench, not a fourth paper review ([[#Decisions]], [[Voron Cascade Bench Checks]]). The HAL has run in LinuxCNC's simulator, not on the machine.
- ==**Gates wiring:** the FlexiHAL's Aux pull-ups (R56, R77, R81 and R82) come off, and all four Aux outputs read open afterwards. Measured on Erik's A7 board on 2026-11-14: 1 kΩ each, which would overheat with an output on at 24 V.==
- ==**Gates wiring:** the nameplates for the 120 V budget. The VFD's is in (`H100-1.5C2-1B`, 110 V single-phase in, read 2026-11-14); the spindle's and the manual's parameter pages are still to come.==
- ==**Before the steps that depend on them:** the FlexiHAL's input resistors before any input is held closed for long (review HW-04), and the step-pulse timing before the drivers are run (review SW-07).==
- ==**Not reviewed:** Rev O's one design change. The door no longer cuts drive power: it acts through LinuxCNC only, and only while the spindle is commanded on (rung 7). Nothing in hardware stops anything when the door opens; the E-stop button is the stop.==
- ==**Accepted limit:** if the FlexiHAL ever answers the Pi but ignores its commands, the E-stop button is the stop (rung 2).==
Wiring design for the Voron Cascade electronics bay. The Cascade manual stops at mounting the parts ("Wiring will be covered separately", p. 236; the two "Wiring" pages are a safety note and three line drawings) and the published sourcing guide is empty, so this note does the job the manual doesn't: it takes the Millennium Machines **Universal Electronics Box** architecture and lays it onto the hardware already in hand — an **Expatria FlexiHAL** running **Remora** with a **Raspberry Pi 5** running **LinuxCNC**, the **StepperOnline 3-CLYS30-V20 closed-loop kit**, the **NDR-480-48** and the **G-Penny H100** VFD, with two supplies swapped (SDR-120-24 for the 24 V, MDR-60-5 for the 5 V). Bench-jog wiring, driver DIP tables and cable colours already live in [[Electronics]]; this note is the panel: mains, contactor, E-stop chain, every FlexiHAL terminal, and where things sit in the bay.
What the UEB contributes is the split: an **un-switched** mains side that keeps the 24 V and 5 V rails (and therefore the Pi and FlexiHAL) alive at all times, and a **contactor-switched** side that feeds the 48 V motor supply and the VFD. On top of that, one thing a fellow Cascade builder uses: a **hardware power latch** (a POWER ON button and a seal-in relay) so a released E-stop never restores power by itself. The enclosure door is an input to LinuxCNC: it stops the spindle and leaves drive power on. There is no POWER OFF button: the operator has an E-stop, POWER ON, CYCLE START, FEED HOLD and AIR ([[#Operator controls]]), and routine power-off is the on-screen E-stop.
Three drawings, generated from `media/cascade-electronics.py` (edit the script, re-run, don't redraw; it writes SVG + PNG next to itself):
| Drawing | File | Shows |
|---|---|---|
| Power one-line + E-stop chain | `media/cascade-power-estop.svg` | Mains → breaker → XT1 → contactor → 48 V / VFD; 24 V and 5 V always-on; the ten-rung control ladder (latch, door relay, contactor, HALT, status, DOOR, air blast, lamps); a what-happens-when table |
| FlexiHAL signal wiring | `media/cascade-flexihal-signals.svg` | Every FlexiHAL terminal: CL57Y ribbons, motor and encoder cables, endstops, buttons and their lamps, door, tool setter / probe, Aux0 → K2, RS485 → VFD, Pi and display |
| Terminal strips | `media/cascade-terminals.svg` | XT1 / XT2 / PE on the rear-panel rail and the K2–K5 + F1 F2 + XT3 group on the upper rail, block by block, with the colour scheme |
![[media/cascade-power-estop.svg]]
![[media/cascade-flexihal-signals.svg]]
![[media/cascade-terminals.svg]]
Bay placement (which rail, which position) is in [[Voron Cascade Electronics Layout]], at **Layout J** — two rails on the gantry plate, the mains terminals on a rear-panel rail, Z1 on the floor; this note and its drawings defer to it and only say what connects to what. These are **functional drawings, not a terminal-level construction set**. Bench-test the E-stop chain on the DIN rail before anything goes in the bay. ==Items in this highlight style are unconfirmed or still to do.==
Companion notes: every setting is in [[Voron Cascade Electrical Configuration]], the bench checks are in [[Voron Cascade Bench Checks]], and the decisions since replaced, in full, and the full changelog are in [[Voron Cascade Electronics Wiring History]].
# Resources
- [Voron Cascade repo](https://github.com/VoronDesign/Voron-Cascade): manual PDF (electrical section pp. 236–267), `CAD/Voron_Cascade_BOM.xlsx`, `STLs/Electronics/` (includes `[pp-p]_flexihal_DIN_mount_pair.stl`)
- [Millennium Machines UEB repo](https://github.com/MillenniumMachines/Universal-Electronics-Box): `Millennium Universal CNC wiring .pdf` (rev 06.09.26) and the assembly manual; [UEB docs](https://millenniummachines.github.io/docs/ueb/)
- [Expatria Flexi-HAL repo](https://github.com/Expatria-Technologies/Flexi-HAL): README (power, isolation, HALT polarity, RS485, stepper pins), schematic rev A7, `Changelog.md`
- [remora-flexi-hal](https://github.com/Expatria-Technologies/remora-flexi-hal): firmware, `TARGET_FLEXIHAL/board_config.h`, `LinuxCNC/ConfigSamples/flexi-hal/` (`remora-flexi.hal`, `remora-flexi.ini`, **`vfdmod_h100-v70.ini`**); [Flexi-Pi](https://github.com/Expatria-Technologies/Flexi-Pi) prebuilt image
- [CL57Y V2.0 manual (PDF)](https://files.omc-stepperonline.com/CL57Y_V2.0_pulse_stepper_driver_manual_V1.0.pdf) · [23HS40-5004D-E1000 datasheet](https://files.omc-stepperonline.com/23HS40-5004D-E1000_Full_Datasheet.pdf) — DIP tables and cable colours are transcribed in [[Electronics]]
- [Mean Well NDR-480 spec](https://www.meanwell.com/Upload/PDF/NDR-480/NDR-480-SPEC.PDF) · [SDR-120 spec](https://www.meanwellaustralia.com.au/sites/default/files/2025-07/MEAN%20WELL%20SDR-120%20DATA%20SHEET.pdf)
- [IronHorse HMC contactor spec sheet](https://cdn.automationdirect.com/static/specs/ironhorsehmcandhtor.pdf) · [Schurter TA35 2-pole](https://www.schurter.com/en/datasheet/TA35_Rocker_2Pole) · [Delta 20DRGS5 (DigiKey)](https://www.digikey.com/en/products/detail/delta-electronics/20DRGS5/2560387)
- [TeamFDM Cascade thread](https://teamfdm.com/forums/topic/3556-voron-cascade-cnc): confirms no wiring guide exists and that a VFD-parameter document is "coming separately"
# Design
## Architecture
```text
120 V / 20 A branch (NEMA 5-20P) ── X1 powerCON inlet ── Q1 TA35 15 A 2P ── XT1 (L / N / PE)
├── PSU2 SDR-120-24 → XT3 (7641K51 strip, upper rail) +24 / 0 V → A1 FlexiHAL, fan, Daylight, F1, F2
├── PSU3 MDR-60-5 → Pi 5 USB-C, display USB-C
└── KM1 1L1 / 5L3 ── XT2 (L-SAFE / N-SAFE)
├── PSU1 NDR-480-48 → 3× CL57Y-V20
└── Z1 Delta 20DRGS5 → U1 H100 VFD → M4 spindle
+24 ── F1 ── SB0 E-stop NC1 ── [SB1 POWER ON NO ∥ K3 seal-in] ── node L ── K3 coil (hardware power latch)
A1 Aux0 ── K2 coil (LinuxCNC enable = E-stop latch OK)
24F ── SQ5 COM-NO ── SQ6 COM-NO ── K5 coil (door relay: both switches pressed = door shut)
node L ── K2 11-14 ── KM1 coil ── 0 V (at K5 A2) (latch AND software enable; the door is not in this rung)
A1 HALT ── SB0 E-stop NC2 (LinuxCNC sees the trip)
A1 Bend ── KM1 21-22 aux NC (open = drive power present)
A1 DOOR ── K5 11-12 NC (common at 0 V) (door open → LinuxCNC stops the spindle, if it is on)
A1 Mist ── K4 coil; +24 ── F2 ── KM1 13-14 ── K4 11-14 ── Y1 air-blast valve (M7 / M9, only with KM1 in)
A1 Start ── SB4 CYCLE START NO; A1 Pause ── SB2 FEED HOLD NO; A1 Aend ── SB5 AIR NO (operator buttons → LinuxCNC)
node L ── R1 ── H1 white; K4 14 ── R5 ── H5 blue; A1 Aux1 ── R2 ── H2 yellow; A1 Aux2 ── R4 ── H4 green (button LEDs, 4.7 kΩ each)
```
## What stays on, what gets switched
| Rail | Source | Switched by | Loads |
|---|---|---|---|
| 24 V | PSU2 SDR-120-24, 5 A (output set to 24.0 V) | nothing (always on) | A1 FlexiHAL (own 1 A fuse), M5 60 mm fan, E1 Daylight bar, K2–K5 coils, KM1 coil (9 W as assumed here, 6 W by the data sheet's table: rung 4; through F1), Y1 air-blast valve (10 W, through F2 and KM1's aux contact) — all via the XT3 strip |
| 5 V | PSU3 MDR-60-5, 10 A (McMaster 3718N152), trimmed to ~5.15 V at the Pi | nothing | A2 Pi 5 via USB-C, A3 display via USB-C; the Pi's 5 V header pins feed the FlexiHAL's isolated MCU domain |
| 48 V | PSU1 NDR-480-48, 10 A, trimmed to 48.0 V | KM1 | U2 / U3 / U4 CL57Y-V20, one 18 AWG twisted pair per driver (black +, white-blue −); the NDR has two +V/−V output pairs, so two feeds share a pair with twin ferrules |
| VFD mains | XT2 via KM1 and Z1 | KM1 | U1 H100 → M4 spindle |
24 V budget: FlexiHAL + sensors ≈ 0.3–0.5 A, fan ≈ 0.15 A, KM1 coil ≈ 0.38 A at most, K2–K5 ≈ 0.07 A, Y1 valve ≈ 0.42 A while blasting, Daylight bar ==unmeasured== → roughly 1.4–1.9 A of the SDR's 5 A. **Never trim the SDR above 24.0 V**: the FlexiHAL input is rated 12–24 V, and the 27 V Zener across it (D16, behind the board's 1 A fuse) is not a clamp to rely on (review HW-08). The SDR's DC-OK relay contact is spare.
5 V: the MDR-60-5 gives 10 A, twice the Pi 5's own 5 A spec, with a DC-OK relay contact (spare). It sits on the un-switched side with the 24 V, so the Pi never reboots on an E-stop. Its output is floating (do not bond −V) because the 5 V is the FlexiHAL's isolated MCU domain. Its OVP (6.25–7.25 V) latches and needs a mains cycle to clear. Set `usb_max_current_enable=1` (no PD negotiation). 78 % efficiency means ~4 W of heat at a typical 2.5 A load.
48 V: the NDR-480-48 (90–264 VAC in, no voltage switch) adjusts 48–55 V and its OVP is 56–65 V; the CL57Y-V20 ceiling is 50 V, so the trimmer stays at **48.0 V**. ==Closed-loop drivers push energy back on hard decels. The supply's OVP does not protect the drivers, because it sits above their 50 V ceiling (review EL06): measure the rail's peak on hard decelerations ([[Voron Cascade Bench Checks]]) and add a 48 V brake / clamp module if it passes 50 V, without waiting for the NDR to latch off.== ==Check the NDR derating curve at 115 VAC; the mill won't pull 480 W, but note it.==
**No DC branch fuses (accepted 2026-11-13, review EL11).** Apart from F1 and F2 on the control ladder and the FlexiHAL's own fuse, the DC wiring relies on each supply's current limit, as the UEB's does. Into a short the NDR-480 limits at about 10.5–13 A and shuts down after 3 s. The SDR-120 gives up to 7.5 A for about 3 s and then shuts its output down, but below about 5.5 A it never trips. The MDR-60-5 does not shut down at all: it holds 10.5–15 A into a short for as long as the short lasts. The thin leads are therefore the exposure: the two USB-C pigtails on the 5 V first, then the fan and Daylight leads on the 24 V. Keep those short, and route and tie them so that they cannot chafe on an edge or get pinched.
## E-stop chain (hardware latch × LinuxCNC enable), and the door
Two independent conditions have to agree before KM1 closes, the hardware latch (K3) and LinuxCNC's enable (K2), and either one dropping removes 48 V and VFD power. The door relay is not a third: it only tells LinuxCNC (rungs 3 and 7):
1. **Rung 1 — hardware latch K3:** XT3 +24 V → **F1 1 A T** → **SB0 E-stop NC1** → [**SB1 POWER ON NO** ∥ **K3 11–14** seal-in] → **node L** → K3 coil; K3 A2 → 0 V. K3 pulls in on POWER ON and holds itself; it drops on E-stop or loss of 24 V, and only a POWER ON press brings it back. There is no OFF button in this rung: an NC STOP contact here would be a second, non-latching E-stop, and routine power-off is the on-screen E-stop acting through K2 (rung 2). Node L (the wire between the seal-in and the K3 coil) is live only while the latch is set.
2. **Rung 2 — software enable K2:** A1 `Aux0+` (24 V via P17) → K2 A1/A2 → `Aux0−`. The FlexiHAL output sinks while the E-stop latch in HAL is OK (`estop_latch.ok-out`, the signal that also lets LinuxCNC leave E-stop): the SPI link is up, HALT is clear, KM1 has not dropped out, the door's backup has not fired (rung 7), and the screen's E-stop has been reset since the last trip. A HALT trip therefore drops K2 at once and it stays out until that reset (review S1). The on-screen E-stop drops K2 too and is the routine power-off. LinuxCNC's enable signal feeds the latch, so K2's command reaches the board in the same servo cycle. After any trip of the latch the SPI link stays up for 0.5 s more and then stops, and from there the firmware's own timeout, 0.7 to 0.8 s by the source, can force every output off if the board did not take the last command (review N01). A reset click on the screen starts the link again, for 0.75 s even if the reset is refused. ==That backstop is not a guarantee, and Erik accepted its limits on 2026-11-15 ([[#Decisions]]). If the board ever answers the Pi but ignores its commands, **the E-stop button is the stop**. Reset clicks a second apart or less keep the board alive, so a refused reset is a reason to stop clicking and look. And until the board lets K2 go, about 1.3 s after a trip, anything that restores KM1's coil circuit (a dip in the 24 V ending, POWER ON after the E-stop button) brings drive power back for up to about a second with the axis still stepping. Where nothing trips the latch (a feed hold, a door stop) there is no backstop at all. The full wording is in [[Voron Cascade Electrical Configuration]], under the HAL.== ==The firmware's timeout is also what drops K2 if LinuxCNC or the Pi dies: measure it (review SW-02).== Machine-off alone leaves the drives powered. The 52003's AC/DC input is rectified, so no external flyback diode.
3. **Rung 3 — door relay K5:** XT3 **24F** (F1 load side) → **SQ5 COM → NO** → XT3:7 → **SQ6 COM → NO** → **K5 A1** direct; A2 → 0 V. Both KW10s pressed (door shut) = K5 energised. The KW10 is SPDT with a *single* common, so one switch cannot sit in a 24 V rung and across a FlexiHAL input at the same time. K5 does the splitting: the switches work its coil at 24 V, and its NC contact, with the common at 0 V, works the DOOR input. Its NO contact, terminal 14, is unused. Two wires per switch.
4. **Rung 4 — contactor:** **node L** → **K2 11–14** → **KM1 A1**; **KM1 A2 → K5 A2**, which is 0 V (K5 A2 is linked to K5 11, and K5 11 goes to XT3 0 V); **HMX1-SSVRC-DC** across the coil. K5 A2 is used here only as a 0 V terminal: the wire shares a twin ferrule there with the A2 ↔ 11 link, and the door is not in this rung (rung 7). Feeding rung 4 from node L means K3 needs only its one changeover contact (the seal-in), which is what lets a 1-CO slimline relay do the job. KM1's coil is why relay contacts, not the FlexiHAL output (≤250 mA, ≥150 Ω), carry it. The coil is taken as 9 W (≈0.38 A) here; the HMC data sheet's coil table (p.13) reads as 6 W (0.25 A) for the DC coil (third review). ==Measure the coil's resistance when the contactor arrives: about 64 Ω is 9 W, about 96 Ω is 6 W.== Either is inside the 52003's 1 A DC-13 at 24 V, and the suppressor keeps the contacts healthy. KM1's poles feed XT2.
5. **Rung 5 — HALT:** **SB0 E-stop NC2** alone between A1 `Halt S` and `Halt G`, so LinuxCNC drops into estop and the GUI shows why power went away. An NC loop is fail-safe (a broken wire reads as a stop). HALT XOR jumper in the **non-default** position for a single NC loop; verify the FlexiHAL HALT LED is off with the E-stop released.
6. **Rung 6 — status:** KM1's built-in aux **21–22 (NC)** → A1 `Bend S/G` → `flexi.input.B_LIMIT`. The contact is closed while KM1 is out and opens when it pulls in, so an *open* contact means "48 V / VFD power present". HAL uses it four ways. It feeds `motion.enable`: LinuxCNC refuses machine-on while KM1 is out, and drops to machine-off, stopping the spindle and mist commands, if KM1 falls out by itself (review SW-03). It un-homes all three axes whenever it closes (`power-lost`). KM1 dropping out after it has been in trips the E-stop latch, so K2 opens and KM1 stays out until the screen reset. A dip in the 24 V that drops KM1 but not K3 then does not bring drive power back by itself, as long as the board takes the command that opens K2 (the accepted limit in rung 2 is the exception), and the loss of drive power lasts long enough to force the re-home (reviews S5 and N02). And the latch cannot be reset while the contact still reads "KM1 in" with the latch tripped. What that detects is a status contact reading "in" when KM1 should be out: a contact or wire that no longer conducts, or a KM1 that has stayed in and shows it. It is not a weld detector: the data sheet's mirror-contact statement (HMC p.16) is for the add-on auxiliary blocks, not for this built-in contact, so a KM1 with a welded main contact may still read "out" (reviews EL07 and R3-03). The status is on the NC pair because the NO pair 13–14 interlocks the valve (rung 9). The price is the failure direction: a contact or wire that stops conducting reads as power present. The reset check finds that at the next E-stop, not when it happens, and the contact runs at 12 V, under the 17 V its data sheet asks for. ==EL07 stays open as a limit of this contact.==
7. **Rung 7 — door to LinuxCNC:** A1 `Door S` → **K5 12 (NC)**; `Door G` → XT3 0 V (the same net as K5 11; the board's `G` pins are common with its 24 V `−` terminal, checked 2026-11-14). K5 released — door open, or F1 blown — closes 11–12 and asserts DOOR. This input is all the door does, and LinuxCNC acts on it only while the spindle is commanded on: it takes the VFD's run command away, stops the feed and aborts the program, and the machine stays on with drive power up and the axes homed. If the spindle command is still there 1 s later, the E-stop latch trips as a backup. With the spindle off an open door does nothing ([[Voron Cascade Electrical Configuration]], the door paragraph under the HAL). The input only ever sees 0 V or open. If the whole 24 V rail is lost, the FlexiHAL's inputs lose their own 12 V supply and DOOR reads false, so that case does not show as DOOR ==(check what LinuxCNC does see: HALT, or nothing)==.
8. **Rung 8 — air blast, K4:** A1 `Mist+` → K4 A1/A2 → `Mist−`. The FlexiHAL sinks the Mist driver on M7 (`iocontrol.0.coolant-mist → flexi.output.MIST`, already in the sample HAL) and releases it on M9.
9. **Rung 9 — valve:** XT3 +24 V → **F2 1 A T** → **KM1 13–14 (aux NO)** → **K4 11–14** → **Y1** (2/2 NC 24 VDC air valve) → 0 V, with the suppressor that is built into the valve's DIN plug (both later reviews read the SC18-LS24-0's data as a Zener, not a plain diode: ==read it off the part==). KM1's contact puts the whole hardware chain in the valve's feed: the E-stop, the on-screen E-stop, a lost 24 V rail or anything else that drops the contactor closes the valve, even with K4 welded or the Mist output stuck on (review S4). The door is not in that chain: the valve works with the door open, and a door stop closes it through LinuxCNC's abort, not in hardware. The valve coil (10 W ≈ 0.42 A) is beyond the FlexiHAL's 250 mA output but inside the 52003's 1 A DC-13. ==The HMC datasheet gives DC-13 figures only for its add-on auxiliary blocks (Q600), not for the built-in pair: read the rating off the contactor when it arrives.== LinuxCNC still drops MIST on any E-stop or machine-off, so the mist state and the blue lamp stay in step with the valve.
10. **Rung 10 — lamps** (the LEDs in the Adafruit 16 mm buttons. They are bare LEDs — ≈2.2 V green / yellow, ≈3 V blue / white — so each gets a **4.7 kΩ ¼ W series resistor at the button**: ≈4.5 mA and 0.1 W on 24 V. ==Go to 2.2 kΩ ½ W (≈10 mA) if they are too dim in shop light.==):
- **H1 white (SB1 POWER ON):** node L → R1 → LED → 0 V. Lit = latch set (armed); dark after an E-stop or a 24 V loss, which is the cue to press it.
- **H5 blue (SB5 AIR):** K4 14 (the switched valve feed, rung 9) → R5 → LED → 0 V. Lit whenever Y1 is energised, whoever asked for it — the button or M7.
- **H2 yellow (SB2 FEED HOLD):** A1 `Aux1+` → R2 → LED → `Aux1−`, driven by `halui.program.is-paused`. Lit while the program is paused.
- **H4 green (SB4 CYCLE START):** A1 `Aux2+` → R4 → LED → `Aux2−`. Steady while a program runs, flashing while it is paused (press to resume), dark when idle.
F1 then carries latch + K5 + KM1 coil + H1 ≈ 0.42 A of its 1 A; H5 rides on F2 with the valve.
Consequences worth knowing:
- The E-stop button acts **in hardware** (K3, KM1); the HALT input only tells LinuxCNC. The door does not act in hardware at all: it is an input to LinuxCNC (rung 7). The on-screen E-stop acts through K2 — software asking a relay — which is fine for a routine power-off and is why the E-stop button stays within reach.
- **Who does what (review S6, accepted 2026-11-12).** The screen's E-stop is the routine stop and power-off. The E-stop button is the disarm that does not depend on the screen, the Pi or K2: it drops K3 and KM1 on its own wiring. Neither isolates anything: for work inside the bay, switch off Q1 and pull the inlet, and shut the air off at the regulator.
- **Anti-restart is hardware** (K3) *and* software (LinuxCNC's enable latch). After an E-stop: release, **POWER ON**, then reset the E-stop and switch the machine on from the screen. After an on-screen E-stop, a cleared HALT fault or lost SPI comms: K2 dropped KM1 but K3 stayed latched (the white lamp is still lit), so the screen's E-stop reset alone restores power. The hardware half has a known limit (review S5, accepted 2026-11-12): a POWER ON button that is held, stuck or welded, or a welded K3 contact, re-arms the latch as soon as the E-stop is released or 24 V returns. That alone cannot restore power after an E-stop, because K2 stays out until the screen reset. A dip in the 24 V that drops KM1 but leaves K3 and K2 in is covered the same way: KM1 dropping out trips LinuxCNC's latch, which opens K2, so that recovery needs the screen reset as well (rung 6). With LinuxCNC or the Pi down, the firmware's timeout has opened K2 and KM1 cannot be in at all. What is left is a drop so short that KM1's status contact closes for less than about 5 ms in all, and the accepted limit in rung 2: a board that ignores the command to open K2.
- Opening the door with the spindle running stops the spindle and aborts the program. Drive power stays on, so the axes hold position and stay homed, but there is no pause-and-carry-on: an aborted program has to be started again. To open the door on purpose, let the program end or stop it first. An E-stop, by contrast, drops motor power: closed-loop steppers lose holding torque, so **re-home after every E-stop**.
- **The door is a convenience interlock in software, not a safety function** (review S2, accepted 2026-11-12; narrowed again on 2026-11-15). It stops the spindle when the door is opened while the spindle is on, and it does that through LinuxCNC, the Pi, the SPI link, the FlexiHAL's DOOR input and the Modbus link to the VFD. Nothing in hardware backs it: a welded K5 contact, a short across the switch run, a switch held shut, a wrong input polarity or a software fault defeats it, and nothing detects that. With the spindle off it does nothing at all, by Erik's choice, so that the axes can be jogged and a probe used with the door open. It is not what keeps hands safe.
- The spindle **coasts** on any drop (VFD loses mains). A programmed stop is a controlled decel over Modbus, and so is a door stop, provided the VFD's stop mode is ramp-to-stop and not coast.
- **Reaching in is a rule, not an interlock** (decided 2026-11-12, review S3). Dropping KM1 removes drive power; it does not stop the spindle, hold Z or lock the door. Hands stay out until the spindle has stopped turning, and Z is treated as free to sink whenever 48 V is off. FEED HOLD, the green lamp and an open door are not permission to reach in. An open door does not remove drive power either: with the door open the axes are powered and will move on a jog, an MDI command or a program that runs with the spindle off. Reaching in with the machine on is the operator's decision each time, as on any open-frame mill: nothing may be commanding motion, and the E-stop button is the stop. ==Measure the coast-down from 24 000 rpm and how far Z sinks with 48 V off, and write both numbers here ([[Voron Cascade Bench Checks]]).==
- CL57Y **ALM** with SW4 OFF is normally open, i.e. high-impedance when healthy — exactly what the FlexiHAL `AL−` expects. Left unconnected for now (open = no alarm, per the bench-jog setup); wiring ALM+ → pin 8 `AL−` and ALM− → pin 7 `GD` later makes a driver fault assert HALT. Until then a stalled or faulted axis goes unnoticed by LinuxCNC while the other axes and the spindle carry on (review HW-06, accepted 2026-11-12: wire the alarms after the first cuts).
- HALT is explicitly "not a safety feature" (Expatria). KM1 is the stop.
- The operator's buttons and lamps — what each does, where it sits and what it is — are in [[#Operator controls]] below.
## Operator controls
Five controls and one plugged hole, approved 2026-11-11. Positions are Layout J coordinates — `a` back from the inside of the front panel, `d` out from the gantry plate toward the door — and left / right are as seen from the front. This section is the wiring of the controls. What the operator sees, and the start-up and recovery sequences in full, are in [[Voron Cascade Electrical Configuration#Button and lamp behaviour (what the operator sees)]]; the panel positions, the button depths and the top-panel box are in [[Voron Cascade Electronics Layout#Operator controls]].
| Ref | Control | Where | Part | Contact | Lamp |
|---|---|---|---|---|---|
| SB0 | **E-stop** | top panel, stock Ø22 hole (a 55.5, d 99.5) | GCX1131 + 2× ECX1030 (2 NC) | NC1 → latch (rung 1); NC2 → `Halt` (rung 5) | — |
| SB1 | **POWER ON** | front panel, right hole (d 120) | Adafruit 1479, white | NO ∥ K3 seal-in (rung 1) | H1 ← node L via R1: lit = latch set |
| SB5 | **AIR** | front panel, left hole (d 40) | Adafruit 1477, blue | NO → `Aend` S / G; LinuxCNC toggles mist | H5 ← K4 14 via R5: lit = valve energised |
| — | AUX | front panel, middle hole (d 80) | Ø10 hole plug | none yet | — |
| SB4 | **CYCLE START** | top-panel box, left (d 29) | Adafruit 1440, green | NO → `Start` S / G; resumes a paused program | H4 ← `Aux2` via R4: steady = running, flashing = paused |
| SB2 | **FEED HOLD** | top-panel box, right (d 59) | Adafruit 1441, yellow | NO → `Pause` S / G; pauses | H2 ← `Aux1` via R2: lit = paused |
- **No POWER OFF button, no red lamp.** A STOP button with NC contacts in the latch and in the HALT loop is electrically a second E-stop that doesn't latch. The E-stop covers the emergency and the screen covers the routine case.
- **Routine power-off is the on-screen E-stop.** K2 follows the E-stop latch in HAL (rung 2), so pressing it drops K2 → KM1 → 48 V and VFD mains while K3 stays latched and the white lamp stays lit. Releasing it on the screen (then machine-on) brings power back. *Machine off* only disables motion; it leaves the drives powered. Only the *off* is software: nothing software does can turn power **on** past a pressed E-stop.
- **Sequence.** Q1 on → 24 V and 5 V up, Pi boots → **POWER ON** (white lights) → release the **E-stop on the screen** (K2 and KM1 pull in) → **machine on** on the screen → home → run. After an E-stop: release → POWER ON → E-stop reset and machine-on on the screen → re-home. After an on-screen E-stop, or KM1 dropping out by itself: E-stop reset and machine-on → re-home, with POWER ON first if the white lamp has gone out. After a door stop (the door opened with the spindle on): shut the door and start the program again; nothing was powered down and nothing needs re-homing. If the reset is refused with the E-stop out, KM1's status contact is reading "in" (rung 6): stop clicking and look (rung 2). The re-home is enforced by the INI and by the HAL's `power-lost` line. ==Prove both on the bench ([[Voron Cascade Bench Checks]], part C).==
- **CYCLE START is resume-only to begin with**, and takes a fresh press made while paused (feed hold, M0 / M1), so a held or stuck button cannot undo a later FEED HOLD. **FEED HOLD only pauses.** ==Decide after some use whether CYCLE START should also start a loaded program from idle (one more `and2` in HAL).==
- **AIR goes through LinuxCNC**, not straight to the valve: each fresh press sends `halui.mist.on` or `.off`, so the button, M7 / M9 and the blue lamp always agree. It works with the door open, and only with the machine switched on, because LinuxCNC refuses coolant commands in E-stop or machine-off. The valve is also interlocked in hardware: its feed runs through KM1's aux contact (rung 9).
- **Contact ratings.** Adafruit publishes none. Three of the four buttons only pull a FlexiHAL input to G (12 V, a few mA). POWER ON makes K3's coil and its own lamp (≈22 mA); pressed with LinuxCNC already out of E-stop it also carries KM1's 0.38 A coil for the few milliseconds until K3 seals in. Making an inductive DC load is gentle. Once K3 has sealed in, K3's contact carries the coil and releasing the button breaks nothing; but a press that is too short, or a bounce before K3 seals, makes the button break that current itself (review EL09). ==Bench-test that case, and put a 52003 behind the button if it objects. Twenty good presses say nothing about how long an unrated contact lasts.==
- **The buttons** are Adafruit 16 mm illuminated momentary pushbuttons (SPST-NO, solder lugs), from the stock in hand — white, green and blue are here, ==the yellow 1441 is not==. Behind the 3 mm front panel they reach 21 mm: AIR ends 3.0 mm in front of the FlexiHAL envelope, so solder its leads and fold them sideways. The stock front holes at d 40 and d 120 open from Ø10 to Ø16, and the top-panel box needs one new cable hole under it (Ø12 at about a 62, d 60), straight above the FlexiHAL.
- **AUX** has no function, no input and no wiring yet: the hole is plugged. `Aux3` is the spare output for its lamp; `Aend` was the last free screw-terminal input and AIR took it, so decide what AUX displaces when it gets a job.
## Mains budget at 120 V
The Cascade inlet hardware is 15 A class: Q1 is a 15 A thermal breaker, and the inlet is a Neutrik powerCON whose family and rating are not settled: the drawings' part number, NAC3MPXXA, is a powerCON XX, not a TRUE1 ==(identify the inlet and the cord actually fitted: review EL04)==. The VFD's nameplate, read 2026-11-14: G-Penny `H100-1.5C2-1B`, 1.5 kW, input 1PH 110 V 50/60 Hz, output 3PH 0–110 V, 12.5 A, 0–1000 Hz. It is the 110 V unit, and it prints no input current. By arithmetic, taking about 80 % for motor and drive together, 1.5 kW at the shaft is about 1.9 kW from the wall: 16 A at 120 V at the very best, and more like 22–28 A at the 0.6–0.7 power factor usual for a single-phase rectifier input with no choke (typical figures, not this unit's). The NDR-480-48 draws 4.8 A at 115 V flat out. So the H100 cannot give its full rating through Q1, or through the 20 A branch either; the breaker and inlet are the limits. The same arithmetic puts the ≈7–8 A motor-current setting below, about 0.9 kW at the shaft, at 9 A from the wall at best and 13–15 A at that power factor, before the supplies are added: it may not be low enough. ==Set the H100 motor-current limit to ≈7–8 A to start with, which is still ~0.8–1 kW at the spindle and more than a desktop mill uses. That is a setting, not a demonstrated mains limit: a VFD's input current is not its motor current, and nothing here shows what the inlet carries with the spindle, the 48 V supply and the rest running together, or while the spindle runs up (review EL01). Measure it at the inlet ([[Voron Cascade Bench Checks]], part E).== If Q1 nuisance-trips under heavy cuts, the answer is a lower current limit or lighter cuts, not a bigger breaker behind the same inlet, and not a 240 V feed: this unit's input is 110 V single-phase. The H100 Modbus note's 220 V does not apply to this unit. Its output tops out at 110 V, so the spindle has to be the 110 V winding ==(check the spindle's plate: 110 V, and its amps against the VFD's 12.5 A)==.
## Grounding and noise
One star point — the **PE group on the rear rail** (blocks 5–10 plain green, jumpered to each other; block 11 a 7641K81 grounding block, which clamps to the rail and bonds it; a 12 AWG wire link from block 10 to block 11, because the green blocks' jumper bar does not fit the 7641K81 — checked on the part 2026-11-12) — and one deliberate lug on every separate piece of metal. Nothing relies on a screw through powder coat or anodize. Every bonding jumper is **12 AWG green/yellow**, the NEC 250.122 size for the 20 A branch breaker: Q1 is a UL 1077 supplementary protector, so it cannot be counted as the branch protection (review EL03). The supply cord is 12/3 for the same reason. One accepted exception (Erik, 2026-11-14): the 48 V −V → PE bond is 18 AWG white/blue, sharing a twin ferrule with U4's −V feed at the NDR. It carries what the NDR can push into a short, not a mains fault ([[#Decisions]]). ==W1's 18 AWG earth core to the spindle and the 16 AWG carriage jumpers are smaller than that and still have to be reconciled (EL03).== ==Check that 12 AWG fits the PSU FG terminals and the inlet's earth tab; a device whose terminal will not take it gets the gauge of its own supply conductors (14 AWG).== Ring terminals McMaster 9388K33, green 10-32 grounding screws 94441A150 in tapped holes, internal-tooth star washers, antioxidant paste on aluminium — the laser cell's hardware.
| # | Point | How | Lands on |
|---|---|---|---|
| 1 | **Steel plate stud** (the bay's main bond) | tapped 10-32 at **a 366, h 120.5** (Layout J: level with the rear rail, 6 mm in front of the block faces, open behind the plate); ==mask the pad — and the two plate rail footprints — before powder coating==, else scrape + paint-piercing washer | PE group |
| 2 | **Rear rail** | bonded by the 7641K81 at block 11, which the 12 AWG link from block 10 feeds | PE group |
| 3 | **Upper and lower rails on the plate** | one **7641K81** each (four in stock, one spare), fed by 12 AWG from the PE group; the **24 V 0 V → PE** bond lands on the upper-rail block (jumper from XT3:12) and the **48 V −V → PE** bond on the lower-rail block (from the NDR −V, 18 AWG: the accepted exception above) — once each. Layout J places the upper one at a 386–392 behind KM1 and the lower one at a 248–254 between the SDR and the VFD, with the drivers at 31 mm pitch instead of 33 to make room (decided 2026-11-13). | PE group (2 feeds) |
| 4 | **U1 VFD** | PE terminal wire. On the printed rail mount the case does not touch the plate, so the wire is its only earth ([[Voron Cascade Electronics Layout#The H100 on the lower rail]]) | PE group |
| 5 | **U2–U4 CL57Y cases** | star washer under one M4 each — optional (SELV); the kit's motor cables have no shield to land here | plate |
| 6 | **Z1, PSU1/2/3 FG, X1 PE pin** | wires as drawn; mounts don't matter; the printed inlet panel and TA35 need nothing | PE group |
| 7 | **2020 frame** | one lug on the bay's rear upright, plate side, door-facing slot, h 160 (Layout J): drop-in T-nut + M5 serrated flange screw through the anodize + ring lug; that is the bay's own frame, so then measure to the base frame and the far corners and add a second lug outside the bay if any reads > 0.1 Ω | PE group |
| 8 | **Bed / table** | bolted through anodize — measure; short jumper to the nearest extrusion if > 0.1 Ω (the tool can touch the workpiece) | frame |
| 9 | **Gantry** (moving) | W19: **high-strand 12 AWG** green/yellow through the drag chain (plain MTW fatigues; Layout J: at about 4.4 mm OD the chain's four cables fill 42 % of a 10×20 — ==caliper the wire and the kit cables==), ring lug + star washer on the gantry plate | PE group |
| 10 | **X carriage → Z carriage** | linear bearings are not a bond (grease film) — measure; 16 AWG flexible jumper across any joint > 0.1 Ω | gantry |
| 11 | **Spindle body** | W1 fourth core at the VFD PE; ==check GX16 pin 4 → body continuity==; if open, a lug on the Z clamp with a jumper to the body | VFD PE |
| — | Working enclosure, doors, bay ACM panels | nothing required (no mains there; KW10s are 24 V; ACM skins bond through their screws into the frame) | — |
Acceptance: ==≤ 0.1 Ω from the inlet PE pin to every point above, with the meter leads nulled, before the first power-up.==
- Single-point bonds, dashed in the drawing: **24 V 0 V → PE** and **48 V −V → PE**, once each, at the rail-local 7641K81s (row 3). Leave the **5 V rail floating** — it is the FlexiHAL's isolated MCU/Pi domain, and bonding it would undo the board's isolation. The MDR-60-5's FG goes to the PE group; its output does not.
- Z1 (Delta 20DRGS5, 20 A two-stage) sits between XT2 and the VFD, as in the UEB: the VFD is the noise source, so the filter isolates it from the PSUs and the mains.
- Spindle cable **W1: 4-core shielded 18 AWG** (the BOM's 3-core cable has no PE conductor). Shield 360° to the VFD PE, floated at the spindle. ==Check continuity from GX16 pin 4 to the spindle body; many G-Penny spindles leave it open — if so, bond the body at the Z clamp.==
- RS485: twisted pair + common, shielded, shield to PE at the VFD end only. The FlexiHAL `GND` on the RS485 block is the **signal common, never the shield** (Expatria).
- The kit's CE2-M2-20 motor cables are **not shielded** (4 × 0.5 mm² RVV); only the encoder cables are (6 × 0.2 mm² RVVP), and their thick black lead is the braid. Leave the braid unconnected unless noise shows up (then EGND only). Keep the IDC ribbons ≥10 cm from motor and spindle cables.
## Terminals and distribution
All three strips are **McMaster 7641K51** blocks (TE Connectivity modular DIN terminal, 6 mm wide, one screw clamp per side, 22–10 AWG, 32 A, 1000 V, choose-a-colour) from stock, with the matching McMaster screw-in jumper bars, end stops and end covers. The two fuses stay in Konnect-It **KN-F10L24DC** fuse terminals. Signals (endstops, probe, tool setter, HALT, DOOR and the three button inputs — Start, Pause, Aend) home-run to the FlexiHAL's own G/S/V terminals; the strips carry only mains, 24 V power and the control-ladder nets. Colour = conductor class, label = circuit:
| Colour | Used for |
|---|---|
| **black** | 120 V line, un-switched (XT1 L) |
| **red** | 120 V line switched by KM1 (XT2 L-SAFE) |
| **white** | grounded conductors: N, N-SAFE, and the 24 V 0 V (the 0 V is bonded to PE, so it is the DC grounded conductor — NFPA 79 white / white-blue) |
| **green / green-yellow** | PE — six plain green 7641K51s, jumpered to each other, with one 7641K81 grounding block at the right-hand end of the rear-rail PE group, linked to them by a 12 AWG wire (the jumper bar does not fit the 7641K81); one more 7641K81 on each plate rail (fed from the group) bonds those rails and takes the 0 V / −V bonds; the plate, frame and gantry are lugs |
| **blue** | +24 V (matches the blue 24 V wire) |
| **gray** | 24 V control nets — 24F, node L, door join — labelled |
| beige, orange, yellow | unused; orange / yellow stay reserved for "live with the inlet unplugged", of which there is nothing here |
**Rear-panel rail — XT1, PE, XT2** (15 blocks = 90 mm + two 8 mm end stops, McMaster 5575N22, + cover + separator ≈ 111–112 mm, on a **119 mm rail**: Erik cut it to sit in the 120 mm between the back panel's uprights, on the stock holes at d 40.3 / 119.3, which leaves about 7 mm. The uprights are a backstop at each end, but the end stops stay, because they are what keeps the row clamped together; 14 AWG for L and N, 12 AWG for PE, one conductor per screw; wire it with the back panel off or before the VFD goes in):
| Block | Net | Colour | Conductors |
|---|---|---|---|
| 1–2 | XT1 L (jumpered) | black | Q1 L out · SDR L · MDR L · KM1 1L1 |
| 3–4 | XT1 N (jumpered) | white | Q1 N out · SDR N · MDR N · KM1 5L3 |
| 5–11 | PE (5–10 jumpered; 11 bonds the rail; 10 ↔ 11 by a 12 AWG wire link) | 5–10 green, 11 = 7641K81 grounding | plate stud · 2020 frame lug · X1 PE · SDR FG · MDR FG · NDR FG · Z1 ground post · U1 PE · gantry jumper · upper-rail 7641K81 feed · lower-rail 7641K81 feed · the 10 ↔ 11 link (one screw on each). The spare is the other screw on block 11 |
| 12–13 | XT2 L-SAFE (jumpered) | red | KM1 2T1 · NDR L · Z1 L (one spare) |
| 14–15 | XT2 N-SAFE (jumpered) | white | KM1 6T3 · NDR N · Z1 N (one spare) |
N (blocks 3–4) and N-SAFE (14–15) are both white, at opposite ends of the rail with the PE group and L-SAFE between them. KM1 switches the neutral too, so never bridge them. The separator plate goes between 11 and 12, where the PE group meets the switched line. The incoming earth and every device earth land on the six jumpered green blocks, so none of them depends on the wire link; the link only bonds the rail. ==The six green blocks need one jumper bar that spans all six: check the stock, or cut one from a longer bar.==
**Upper rail, in the gap between the relays and KM1 — K2–K5, F1 F2, XT3.** Layout J (fit test of 2026-11-13, zero collisions): K2 K3 K4 K5 at a 202–226.8 → 8 mm end stop → F1 F2 at a 234.8–250.8 → XT3 at a 250.8–325.6 → end stop to a 333.6 → KM1 at a 340–385 → upper-rail 7641K81 at a 386–392. The K4 → KM1 gap is **119.4 mm**; with the 8 mm end stops in hand (McMaster 5575N22) the group is 113.0 mm with the 2.8 mm end cover Entrelec lists, which leaves 6.4 mm, or 112.2 mm with a 2 mm cover, which leaves 7.2 mm. ==The end cover is still unmeasured; KM1 can slide back about 6 mm if needed.== XT3's ~25 control wires land 28 mm above the VFD's top, in its exhaust — route them up and forward, not down across the vents.
| XT3 | Net | Colour | Conductors landed |
|---|---|---|---|
| 1–3 | **+24 V** (jumpered) | blue | SDR +V · A1 24V in · M5 fan · E1 Daylight · F1 in · F2 in |
| 4–5 | **24F** = F1 load side (jumpered) | gray | F1 out · SB0 E-stop NC1 in · SQ5 COM (one spare) |
| 6 | **node L** | gray | SB1 POWER ON NO out ↔ K3 14 (K3 14–A1 linked at the relay) |
| 7 | door join | gray | SQ5 NO ↔ SQ6 COM (SQ6 NO → K5 A1 direct) |
| 8–12 | **0 V** (jumpered) | white | SDR −V · A1 0 V · M5 · E1 · K3 A2 · K5 11 (linked to K5 A2, which also takes KM1 A2) · Y1 · H1 / H5 lamp return · A1 Door G · 0 V → PE bond jumper to the upper-rail 7641K81 |
| F1 | 1 A T in KN-F10L24DC | — | in: XT3:3 · out: XT3:4 — one conductor per side |
| F2 | 1 A T in KN-F10L24DC | — | in: XT3:3 · out: KM1 13 (then KM1 14 → K4 11) |
Keeping the strip at twelve blocks means a few doubled conductors: **SB0 NC1 out** (a screw terminal on the E-stop's contact block) takes the wire to K3 11 *and* the short hop to SB1's NO lug; **SB1 NO out** (a solder lug) takes the node L wire *and* R1 for H1; **K4 14** takes Y1's feed *and* the H5 lamp wire (twin ferrule); **K3 14 ↔ A1** and **K5 A2 ↔ 11** are short links at the relays, and **K5 A2** also takes KM1's coil return (twin ferrule with the link); **H1 − ↔ H5 −** are joined along the front panel so one 0 V return comes back. The front corner — E-stop on the top panel, POWER ON and AIR in the front panel — therefore comes to the upper rail as 24F, K3 11, node L, the K4 14 lamp feed and one 0 V return; the E-stop's NC2, AIR's contact and the whole top box (two contacts, two lamps) go straight to FlexiHAL terminals; the two door switches come as COM + NO each. Everything else on the ladder is a short jumper between devices on the upper rail (K2–K5, F1 F2, XT3, KM1) or a direct pair to a FlexiHAL terminal.
## Lower rail and VFD mount
The lower rail (a 21.5–352, 330.5 mm, four M5 screws at a 40 / 140 / 240 / 340) carries the three drivers, the NDR-480, the SDR-120, the lower grounding block and, on a printed mount Erik is designing, the H100. The hole positions and the marking jig are in [[Voron Cascade Electronics Layout#Drill and tap list]]; the reference drawing for the mount and what it has to clear are in [[Voron Cascade Electronics Layout#The H100 on the lower rail]]. What matters for the wiring: the printed mount keeps the VFD's case off the plate, so its PE terminal wire is its only earth ([[#Grounding and noise]], row 4).
## Cable schedule
| # | From → to | Conductors | Route | Notes |
|---|---|---|---|---|
| W1 | U1 U/V/W/PE → M4 spindle | 4 × 18 AWG shielded | to the spindle by the machine's own carrier — ==not the bay drag chain; confirm the route== | shield → VFD PE only |
| W2 / W3 / W4 | U2 / U3 / U4 → M1 / M2 / M3 motor | CE2-M2-20 motor cable, 4 × AWG20, GX16 at the motor | one axis through the bay drag chain ==(which — confirm)==; the others per Layout J / frame slots | BK A+, GN A−, RD B+, BU B− |
| W2e / W3e / W4e | M1 / M2 / M3 encoder → U2 / U3 / U4 | CE2-M2-20 encoder cable, AWG26, DB15 at the motor | same as the motor cable | YE EB+, GN EB−, thin BK EA+, BU EA−, RD VCC, WH EGND; thick BK n/c |
| W5–W7 | SQ1/SQ2/SQ3 → A1 Xend/Yend/Zend | 3 × 24 AWG (BN/BU/BK) | one endstop through the bay drag chain; the others per Layout J / frame slots | BN→V (12 V), BU→G, BK→S |
| W8 | A1 RS485 A/B/GND → U1 RS+/RS−/COM | 2-pair 24 AWG twisted, shielded | inside bay | ≤1 m |
| W9–W11 | A1 X/Y/Z IDC → U2/U3/U4 | 8-way 1.27 mm ribbon + 2×4 IDC | inside bay | 1 S+→PU+, 2 S−→PU−, 3 D+→DR+, 4 D−→DR−; 5–6 empty; 7 and 8 empty for now. The optional alarm needs both: 7 GD → ALM−, 8 AL− → ALM+ |
| W12 | SQ4 tool setter → A1 TOOL S/G | 20 AWG blue (S) + 18 AWG white-blue (G) | under the table | |
| W13 | SQ5, SQ6 → XT3:4 / XT3:7 / K5 A1 (rung 3) | 2 × 20 AWG blue per switch (COM, NO) | working enclosure frame | COM-NO in series through XT3:7; NC pins unused |
| W14 | XT3 24F → SB0 NC1 → K3 11, with a short hop from the same SB0 screw to SB1 NO; SB1 NO out → XT3:6 node L (latch chain); SB0 NC2 → A1 Halt S / G | 20 AWG blue (latch chain); HALT S 20 AWG blue, G 18 AWG white-blue | top panel and front panel, door-side corner | SB0: GCX screw terminals; SB1: solder lugs, heat-shrink each joint |
| W22 | Front-panel lamps and AIR: SB1 NO out → R1 → H1 (at the button); K4 14 → R5 → H5; H1 − ↔ H5 − → one return to XT3 0 V; SB5 NO → A1 Aend S / G | 20 AWG blue (lamp feeds, Aend S); 18 AWG white-blue (lamp return, Aend G) | front panel | resistors soldered at the LED + lug and sleeved; 18 AWG is heavy for these lugs, so solder it flat against the lug, heat-shrink it and tie the bundle down close by; AIR is 3 mm from the FlexiHAL — fold its leads sideways |
| W24 | Top box: SB4 NO → A1 Start S / G; SB2 NO → A1 Pause S / G; A1 Aux2+ → R4 → H4 → Aux2−; A1 Aux1+ → R2 → H2 → Aux1− | one 6-core 24–26 AWG cable | through the new Ø12 hole under the box, straight down to the FlexiHAL | 6 cores: the two G pins and the two Aux + pins are common on the board (checked with a meter, 2026-11-14); leave a loop so the box lifts off |
| W23 | K5 12 → A1 Door S; XT3 0 V → A1 Door G | 20 AWG blue (S) + 18 AWG white-blue (G) | inside bay | rung 7 |
| W25 | KM1 21 → A1 Bend S; KM1 22 → A1 Bend G | 18 AWG blue (S) + 18 AWG white-blue (G) | inside bay, upper rail to the FlexiHAL | rung 6: KM1's NC aux, open = drive power present |
| W15 | X1 → Q1 → XT1 (rear rail); XT1 → PSU2 and PSU3, un-switched; XT1 → KM1 (upper rail) → XT2 (rear rail) → PSU1, and → Z1 → U1 | 14 AWG | inside bay | BOM has only 1 m; plan on 4 m |
| W16 | PSU1 → U2/U3/U4 V+/V− | 2 × 18 AWG twisted per driver (black +, white-blue −) | inside bay | one feed per driver; the NDR-480 has only two +V/−V pairs, so U2 + U3 land in one pair with **twin-wire ferrules** (2 × 18 AWG) and U4 in the other |
| W17 | XT3 +24 / 0 V → A1, M5, E1 | 20 AWG blue (+24), 18 AWG white-blue (0 V) | inside bay | |
| W18 | PSU3 → A2, A3 | bare-wire → USB-C cables (BOM) | inside bay / front panel | the display also takes HDMI and USB touch from the Pi; a back-panel USB-C keystone serves a keyboard or stick |
| W19 | PE group → plate stud, 2020 frame lug (its own wire from the PE group, as the label table has it), gantry lug, upper/lower-rail 7641K81s, PSU1/PSU2/PSU3 FG, Z1, U1 PE | 12 AWG green/yellow; **high-strand** for the gantry run | bay + drag chain | bonding plan under Grounding |
| W21 | XT3 → F2 → KM1 13–14 → K4 → Y1 | 20 AWG blue + 18 AWG white-blue | bay → wire guard → Y1 **outside the cabinet**, at the regulator | 24 VDC; DIN plug with built-in suppressor + LED at the valve; the air line, not the cable, goes through the chain |
| W20 | XT3 +24 → F1 → 24F; XT3:6 → K3 14/A1; node L → K2 11-14 → KM1 A1; KM1 A2 → K5 A2 (0 V); K5 11 → XT3 0 V; SQ6 NO → K5 A1; F2 → KM1 13, KM1 14 → K4 11 | 20 AWG blue; 18 AWG white-blue for the 0 V wires; 18 AWG blue to KM1 (A1, 13 / 14); KM1 A2 is a 0 V wire, 18 AWG white-blue | upper rail | 24 VDC; F1 feeds the latch, K5 and KM1 |
All machine cables enter the bay through the single wire-guard hole in the side panel (manual p. 237–238). The bay drag chain carries **one motor cable, its encoder cable, one endstop cable and the PE jumper** — about 42 % of a 10×20 chain by Layout J's fill estimate, with the 12 AWG jumper (typical cable diameters; ==caliper the kit cables==). A **4 mm air line** then fits only on top of the encoder cable; a 6 mm one does not fit a 10×20 and needs the BOM's 15×15 chain.
## Wire numbers and labels
Every conductor is numbered and labelled at both ends, following [[Industrial Control Panel Wire Size and Color Standards]]: NFPA 79 asks for identification at each termination that matches the documentation, and the shop rule there is "number every wire, both ends". Until the numbers are on the drawings, the tables below are that documentation.
- **Wire number = the net.** Every conductor on the same electrical node carries the same number, and the number changes at every fuse, contact, coil or filter. The rails are named as in the standards note: `24P` / `24N`, `48P` / `48N`, `5P` / `5N`.
- **Each end's label = wire number + the terminal that end lands on**: `24F XT3:5` at the strip, `24F SB0:11` at the E-stop. A wire that has come off says where it goes back; the number says what it is.
- **Wires that home-run to the FlexiHAL take the FlexiHAL terminal's name** (`HALT-S`, `AUX0+`, `MIST-`), because the board, not a terminal strip, is what joins them. At the board end the label is the name plus `A1`.
- **Jacketed cables** get one label on the jacket at each end: the cable number from the [[#Cable schedule]] and what that end plugs into. Their cores are identified by colour, which both standards accept for multiconductor cable.
- **Terminal blocks** carry their block number: McMaster marker cards 7641K75 (numbered 1–100) or 7641K19 (blank) fit the 7641K51 blocks ([[DIN Terminal Blocks]]).
- **Making the labels:** heat-shrink sleeves from the Dymo Rhino ([[Dymo Heat Shrink Labels]]) — the 1/4 in cartridge (DYMO 18051 white, 18052 yellow) for single wires from 22 to 14 AWG, the 1/2 in or 3/4 in for cable jackets. Slide the sleeve on before the ferrule. Every single wire is 20 AWG or heavier, inside that sleeve's range; the thinner cores of W24 and the sensor leads are identified by colour and the label on the jacket.
| Wire no. | Net | Wire |
|---|---|---|
| `L0` `N0` | Mains between the inlet X1 and the breaker Q1 | black / white, 14 AWG |
| `L1` `N1` | Un-switched mains after Q1 (XT1) | black / white, 14 AWG |
| `L2` `N2` | KM1-switched mains (XT2, "L-SAFE / N-SAFE") | black / white, 14 AWG |
| `L3` `N3` | Filtered mains, Z1 → VFD | black / white, 14 AWG |
| `PE` | Protective earth and bonding | green/yellow, 12 AWG |
| `48P` `48N` | 48 V motor rail — DC power, so black, with the bonded return white/blue | black / white-blue, 18 AWG twisted |
| `24P` `24N` | 24 V rail (XT3 1–3 and 8–12) | blue 20 AWG / white-blue 18 AWG |
| `5P` `5N` | 5 V to the Pi and the display (floating) | the USB-C cables' own cores |
| `24F` | F1 load side (XT3 4–5) | blue, 20 AWG |
| `ES` | After the E-stop's NC1: SB0 12, K3 11, SB1 | blue, 20 AWG |
| `LAT` | Node L, the latched 24 V (XT3 6) | blue, 20 AWG |
| `DR1` `DR2` | Door chain: SQ5 NO ↔ SQ6 COM (XT3 7); SQ6 NO → K5 A1 | blue, 20 AWG |
| `KM+` | KM1 coil feed: K2 14 → KM1 A1. The coil's return, KM1 A2 → K5 A2, is on the 0 V net and is numbered `24N` | blue, 18 AWG |
| `24F2` | F2 load side → KM1 13 | blue, 18 AWG |
| `24K` | After KM1's aux contact: KM1 14 → K4 11 | blue, 18 AWG |
| `Y1+` | K4 14 → the valve and the AIR lamp | blue, 20 AWG |
| FlexiHAL names | One wire per FlexiHAL terminal, named after it | 20 AWG blue for S and +, 18 AWG white-blue for G and −; the cores of W24 by colour |
**Panel wire is the MTW on the shelf (2026-11-12):** 14 AWG black, white and green/yellow; 18 AWG blue and white/blue; 20 AWG blue. Every + and S conductor is 20 AWG blue and every 0 V, G and − conductor is 18 AWG white/blue. The wires that land on KM1's coil feed and auxiliary terminals (`KM+`, `24F2`, `24K`, `BEND-S`) are 18 AWG blue; the wire on KM1 A2 is a 0 V conductor (`24N`), so it is 18 AWG white/blue like the other 0 V wires. For all of them: the HMC datasheet gives 18–10 AWG for its auxiliary contact blocks and no separate figure for the coil terminals, ==so check that an 18 AWG ferrule clamps firmly when the contactor arrives==. No single wire is thinner than 20 AWG, which keeps every conductor inside the 7641K51's 22–10 AWG range and the 28–16 AWG of the plugs for the FlexiHAL's 3.5 mm headers. Only jacketed cables stay thinner: the sensor leads, RS485 and the top-box multicore. `48P` is 18 AWG black, ordered 2026-11-12 together with 18 AWG white; nothing in this design uses the 18 AWG white yet. PE bonding is 12 AWG green/yellow, ==still to buy==; the 14 AWG green/yellow is the fallback for a device earth terminal that will not take 12.
Colours are the standards note's cheat sheet applied to this machine. Terminal shorthand: `XPE` is the PE group on the rear rail (blocks 5–11); `PEU` and `PEL` are the grounding blocks on the upper and lower plate rails; `PLATE`, `FRAME` and `GANTRY` are the bonding lugs; `SB0:11–12` is the E-stop's first NC block and `21–22` its second; on the 16 mm buttons `:1` and `:2` are the switch lugs and `:+` / `:-` the LED lugs. ==Q1, Z1 and the VFD's mains terminals are named by function here (`L-IN`, `LINE-L`, `U1:L`); check them against the parts' own markings and correct the labels if they differ.== Within a jumpered group any block is electrically the same; the block numbers below are a suggested allocation that keeps one conductor per screw.
**Mains — W15, 14 AWG**
| Wire no. | End A label | End B label | Note |
|---|---|---|---|
| L0 | `L0 X1:L` | `L0 Q1:L-IN` | |
| N0 | `N0 X1:N` | `N0 Q1:N-IN` | |
| L1 | `L1 Q1:L-OUT` | `L1 XT1:1` | |
| N1 | `N1 Q1:N-OUT` | `N1 XT1:3` | |
| L1 | `L1 XT1:1` | `L1 KM1:1L1` | |
| N1 | `N1 XT1:3` | `N1 KM1:5L3` | |
| L1 | `L1 XT1:2` | `L1 PSU2:L` | SDR-120-24 |
| N1 | `N1 XT1:4` | `N1 PSU2:N` | |
| L1 | `L1 XT1:2` | `L1 PSU3:L` | MDR-60-5 |
| N1 | `N1 XT1:4` | `N1 PSU3:N` | |
| L2 | `L2 KM1:2T1` | `L2 XT2:12` | |
| N2 | `N2 KM1:6T3` | `N2 XT2:14` | |
| L2 | `L2 XT2:12` | `L2 PSU1:L` | NDR-480-48 |
| N2 | `N2 XT2:14` | `N2 PSU1:N` | |
| L2 | `L2 XT2:13` | `L2 Z1:LINE-L` | |
| N2 | `N2 XT2:15` | `N2 Z1:LINE-N` | |
| L3 | `L3 Z1:LOAD-L` | `L3 U1:L` | |
| N3 | `N3 Z1:LOAD-N` | `N3 U1:N` | |
**Protective earth and bonding — W19, 12 AWG green/yellow**
| Wire no. | End A label | End B label | Note |
|---|---|---|---|
| PE | `PE XPE:5` | `PE PLATE` | plate stud |
| PE | `PE XPE:5` | `PE FRAME` | 2020 frame lug |
| PE | `PE X1:PE` | `PE XPE:6` | incoming earth |
| PE | `PE XPE:6` | `PE PEL` | feed to the lower-rail grounding block |
| PE | `PE XPE:7` | `PE PSU2:FG` | |
| PE | `PE XPE:7` | `PE GANTRY` | high-strand, through the drag chain |
| PE | `PE XPE:8` | `PE PSU3:FG` | |
| PE | `PE XPE:8` | `PE PSU1:FG` | |
| PE | `PE XPE:9` | `PE Z1:PE` | filter ground post |
| PE | `PE XPE:9` | `PE U1:PE` | |
| PE | `PE XPE:10` | `PE PEU` | feed to the upper-rail grounding block |
| PE | `PE XPE:10` | `PE XPE:11` | wire link from the jumpered green blocks to the grounding block, block 11, which bonds the rail: the jumper bar does not fit the 7641K81. The other screw on block 11 is the spare |
| 24N | `24N XT3:12` | `24N PEU` | the one 0 V → PE bond; add a `0V-PE LINK` tag |
| 48N | `48N PSU1:-V` | `48N PEL` | the one −V → PE bond, sharing U4's −V terminal (twin ferrule); add a `48N-PE LINK` tag. It is 18 AWG white/blue, not the 12 AWG of the rest of this table: accepted by Erik as a deviation on 2026-11-14 (reviews EL03, D1; [[#Decisions]]) |
Any bonding jumper added after the continuity check (bed, carriages, spindle body) is `PE` plus the point it lands on.
**48 V — W16, 18 AWG twisted pair per driver: black and white-blue**
| Wire no. | End A label | End B label | Note |
|---|---|---|---|
| 48P | `48P PSU1:+V` | `48P U2:V+` | X driver; shares a +V terminal with U3 (twin ferrule) |
| 48N | `48N PSU1:-V` | `48N U2:V-` | |
| 48P | `48P PSU1:+V` | `48P U3:V+` | Y driver |
| 48N | `48N PSU1:-V` | `48N U3:V-` | |
| 48P | `48P PSU1:+V` | `48P U4:V+` | Z driver; the second +V / −V pair |
| 48N | `48N PSU1:-V` | `48N U4:V-` | |
**24 V distribution — W17, 20 AWG blue and 18 AWG white-blue**
| Wire no. | End A label | End B label | Note |
|---|---|---|---|
| 24P | `24P PSU2:+V` | `24P XT3:1` | |
| 24N | `24N PSU2:-V` | `24N XT3:8` | |
| 24P | `24P XT3:1` | `24P A1:24V+` | FlexiHAL supply |
| 24N | `24N XT3:8` | `24N A1:24V-` | |
| 24P | `24P XT3:2` | `24P M5:+` | fan |
| 24N | `24N XT3:9` | `24N M5:-` | |
| 24P | `24P XT3:2` | `24P E1:+` | Daylight bar |
| 24N | `24N XT3:9` | `24N E1:-` | |
| 24P | `24P XT3:3` | `24P F1:IN` | |
| 24P | `24P XT3:3` | `24P F2:IN` | |
**Control ladder — W20 on the upper rail, W14 to the E-stop and POWER ON, W13 to the doors, W21 and W22 to the valve and front-panel lamps**
| Wire no. | End A label | End B label | Run, note |
|---|---|---|---|
| 24F | `24F F1:OUT` | `24F XT3:4` | W20 |
| 24F | `24F XT3:5` | `24F SB0:11` | W14 |
| ES | `ES SB0:12` | `ES K3:11` | W14 |
| ES | `ES SB0:12` | `ES SB1:1` | W14, the short hop from the same SB0 screw |
| LAT | `LAT SB1:2` | `LAT XT3:6` | W14; R1 for the white lamp is soldered from SB1:2 to SB1:+ at the button |
| LAT | `LAT XT3:6` | `LAT K3:14` | W20 |
| LAT | — | — | link K3 14 → K3 A1 at the relay, too short to label |
| LAT | `LAT K3:A1` | `LAT K2:11` | W20; the note above does not say where K2 11 picks up node L, and this link keeps XT3 at 12 blocks |
| 24N | `24N K3:A2` | `24N XT3:10` | W20 |
| KM+ | `KM+ K2:14` | `KM+ KM1:A1` | W20, 18 AWG blue |
| 24N | `24N KM1:A2` | `24N K5:A2` | W20, 18 AWG white-blue. KM1's coil return, on the 0 V net. Shares K5 A2 with the A2 → 11 link: 2 × 1.0 mm² twin ferrule |
| 24N | `24N K5:11` | `24N XT3:10` | W20; link K5 A2 → K5 11 at the relay, unlabelled. Two 18 AWG share K5 11, and two share K5 A2: a 2 × 1.0 mm² twin ferrule on each ==and check that both seat in the 52003's clamps== |
| 24F | `24F XT3:4` | `24F SQ5:COM` | W13 |
| DR1 | `DR1 SQ5:NO` | `DR1 XT3:7` | W13 |
| DR1 | `DR1 XT3:7` | `DR1 SQ6:COM` | W13 |
| DR2 | `DR2 SQ6:NO` | `DR2 K5:A1` | W13 |
| 24F2 | `24F2 F2:OUT` | `24F2 KM1:13` | W20, 18 AWG blue |
| 24K | `24K KM1:14` | `24K K4:11` | W20, 18 AWG blue; KM1's NO aux puts the contactor in the valve's feed (rung 9) |
| Y1+ | `Y1+ K4:14` | `Y1+ Y1:1` | W21, to the valve's DIN plug |
| 24N | `24N Y1:2` | `24N XT3:11` | W21 |
| Y1+ | `Y1+ K4:14` | `Y1+ SB5:R5` | W22, twin ferrule at K4 14; lands on the free end of R5 at the AIR button |
| 24N | `24N SB5:-` | `24N SB1:-` | W22, the lamp returns joined along the front panel |
| 24N | `24N SB1:-` | `24N XT3:11` | W22; two 18 AWG meet on the small SB1 − lug |
**FlexiHAL signals — single wires, 20 AWG blue for S and +, 18 AWG white-blue for G and −**
| Wire no. | FlexiHAL end | Far end | Run, note |
|---|---|---|---|
| AUX0+ | `AUX0+ A1` | `AUX0+ K2:A1` | K2 coil |
| AUX0- | `AUX0- A1` | `AUX0- K2:A2` | |
| MIST+ | `MIST+ A1` | `MIST+ K4:A1` | K4 coil |
| MIST- | `MIST- A1` | `MIST- K4:A2` | |
| HALT-S | `HALT-S A1` | `HALT-S SB0:21` | W14 |
| HALT-G | `HALT-G A1` | `HALT-G SB0:22` | W14 |
| BEND-S | `BEND-S A1` | `BEND-S KM1:21` | W25; KM1's NC aux: open = power present; 18 AWG blue |
| BEND-G | `BEND-G A1` | `BEND-G KM1:22` | W25 |
| DOOR-S | `DOOR-S A1` | `DOOR-S K5:12` | W23 |
| DOOR-G | `DOOR-G A1` | `DOOR-G XT3:12` | W23 |
| AEND-S | `AEND-S A1` | `AEND-S SB5:1` | W22, AIR button |
| AEND-G | `AEND-G A1` | `AEND-G SB5:2` | W22 |
| START-S | `START-S A1` | `START-S SB4:1` | W24, CYCLE START |
| PAUSE-S | `PAUSE-S A1` | `PAUSE-S SB2:1` | W24, FEED HOLD |
| START-G | `START-G A1` | `START-G SB4:2` | W24; jumpered on to SB2:2 inside the box |
| AUX2+ | `AUX2+ A1` | `AUX2+ BOX` | W24; feeds R4 and R2 inside the box |
| AUX2- | `AUX2- A1` | `AUX2- SB4:-` | W24, green lamp |
| AUX1- | `AUX1- A1` | `AUX1- SB2:-` | W24, yellow lamp |
W24 is six cores: the G pins and the Aux + pins are common on the board (checked 2026-11-14), so `PAUSE-G` and `AUX1+` are not run. The W24 rows are cores of the top-box cable, identified by colour; they are not panel wire.
**Jacketed cables — one label on the jacket at each end, cores by colour**
| Cable | Bay-end label | Far-end label | Cores |
|---|---|---|---|
| W1 | `W1 U1 SPINDLE` | `W1 M4` | U, V, W and PE marked at the VFD; shield to the VFD's PE only |
| W2 / W3 / W4 | `W2 U2 MOTOR` / `W3 U3 MOTOR` / `W4 U4 MOTOR` | `W2 M1 X` / `W3 M2 Y` / `W4 M3 Z` | BK A+, GN A−, RD B+, BU B− |
| W2e / W3e / W4e | `W2E U2 ENC` / `W3E U3 ENC` / `W4E U4 ENC` | `W2E M1 X` / `W3E M2 Y` / `W4E M3 Z` | YE EB+, GN EB−, thin BK EA+, BU EA−, RD VCC, WH EGND |
| W5 / W6 / W7 | `W5 A1 XEND` / `W6 A1 YEND` / `W7 A1 ZEND` | `W5 SQ1 X` / `W6 SQ2 Y` / `W7 SQ3 Z` | BN → V, BU → G, BK → S |
| W8 | `W8 A1 RS485` | `W8 U1 RS485` | A → RS+, B → RS−, GND → COM; shield to PE at the VFD only |
| W9 / W10 / W11 | `W9 A1 X` / `W10 A1 Y` / `W11 A1 Z` | `W9 U2` / `W10 U3` / `W11 U4` | ribbon pins 1 PU+, 2 PU−, 3 DR+, 4 DR− |
| W12 | `W12 A1 TOOL` | `W12 SQ4` | S and G |
| W13 | cores labelled as in the ladder table | `W13 SQ5` / `W13 SQ6` | one two-core cable per door switch |
| W18 | `W18A PSU3` / `W18B PSU3` | `W18A A2 PI` / `W18B A3 DISPLAY` | cores `5P PSU3:+V` and `5N PSU3:-V` |
| W21 | cores labelled as in the ladder table | `W21 Y1` | `Y1+` and `24N` |
| W24 | cores labelled as in the FlexiHAL table | `W24 TOP BOX` | six cores |
## Parts beyond what's in hand
| Ref | Part | Why |
|---|---|---|
| KM1 | **IronHorse HMC-18B30-11-DS** (18 A AC-3 / 40 A AC-1, 3 NO + 1NO/1NC aux, 24 VDC coil: 9 W as this note has taken it, 6 W in the data sheet's coil table, to be measured), AutomationDirect $49 | Replaces the BOM's WEG CWC025-00-30V18 (120 V coil, ordered 2026-05-19 — now spare): the control chain stays at 24 V, and the two aux contacts interlock the valve (NO 13–14) and give the status signal (NC 21–22) |
| — | **IronHorse HMX1-SSVRC-DC** surge suppressor (24–48 VDC), AutomationDirect $12 | Across KM1 A1–A2; protects K2's contact |
| PSU2 | **Mean Well SDR-120-24** (24 V 5 A, DIN, DC-OK), DigiKey $56.10 | Replaces the owned HDR-30-24 (1.5 A — too little once the contactor coil joins); same part as the laser cell's PS1. The HDR-30-24 becomes the bench supply |
| PSU3 | **Mean Well MDR-60-5** (5 V / 10 A, 50 W, 85–264 VAC, 40 × 90 × 100 mm, DC-OK relay), McMaster **3718N152** $55.41 | Replaces the owned HDR-30-5 (3 A was marginal for Pi 5 + display), which becomes a bench supply |
| K2–K5 | 4× **Murrelektronik 52003** (MIRO 6.2, 24 V AC/DC input 17 mA, 1 CO, 6 A AC-12 / 1 A DC-13 @ 24 V, 6.2 mm wide, LED) — from the laser-cell stock | K2 = LinuxCNC enable relay, in while LinuxCNC is out of E-stop (the Scylla's on-board relay in the UEB); K3 = hardware power latch (POWER ON + seal-in); K4 = air-blast valve driver; K5 = door relay. 24.8 mm of rail; rectified input, so no external diode |
| Y1 | 2/2 NC 24 VDC air solenoid valve, 1/4" NPT — **NITRA DVD-2AC2A-24D** (brass, Cv 1.55, 1–180 psi, 10 W, 18 mm DIN coil), AutomationDirect $93; any ≤1 A 24 VDC 2/2 NC valve works | Air blast on M7. Pair with a DIN 43650-A plug with built-in suppressor + LED (SC18-LS24-0; a Zener by the reviews' reading of its data) |
| F2 | 5 × 20 mm **1 A** time-delay fuse in a second **KN-F10L24DC** fuse terminal (8 mm, blown-fuse LED; laser stock) | Protects the valve branch wiring (KM1 13–14, K4 11–14, Y1). Like F1, it clears a fault but does not hold it to 1 A |
| — | Regulator + filter upstream of Y1 (outside the cabinet), push-fit fittings and tubing — **4 mm OD through the 10×20 drag chain** (6 mm only with the 15×15 chain), Loc-Line or similar nozzle on the spindle clamp | The air side; nothing electrical |
| F1 | 5 × 20 mm **1 A** time-delay fuse in a Konnect-It **KN-F10L24DC** fuse terminal — both from the laser-cell stock (F1 and F4 there are spare since the laser's Rev F) | Protects the wiring of the latch, K5 and KM1 coil branch, which has no other protection. It does not hold a fault to 1 A: a time-delay fuse passes several times its rating until it clears, and the SDR-120 can supply 7.5 A for about 3 s. Nothing here shows that the 52003's contacts, rated 6 A, survive that, or whether fuse or contact gives way first: the fuse's clearing data and the relay's short-time rating have not been compared ==(review EL08, open)==. The relay's 1 A DC-13 figure is its switching rating for the coil loads |
| XT1–XT3 | **McMaster 7641K51** (TE modular DIN block, 6 mm, 22–10 AWG, 32 A; $2.33) from stock — 26 blocks: 2 black, 9 white, 6 green, 2 red, 3 blue, 4 gray — plus three **7641K81** grounding blocks (TE 1SNA165113R1600, 6 mm, bond to the rail; $8.06, four in stock, so one is spare): one at the right-hand end of the rear-rail PE group (linked to the green blocks by wire: the jumper bar does not fit it), one on each plate rail, plus the 7641K-series screw-in jumper bars (2-, 3-, 5-position or cut; the rear-rail PE group needs one that spans six), 4 end stops (McMaster 5575N22, 8 mm), 2 end covers, 1 separator plate | XT1 / PE / XT2 on the rear-panel rail (15), XT3 on the upper rail (12), a 7641K81 at the end of each plate rail. Replaces the BOM's three Wago 221-415 mounts |
| SB1 | **Adafruit 1479** — 16 mm illuminated pushbutton, white, momentary SPST-NO (in hand) | POWER ON, front panel right hole; lamp H1 = latch set (node L via R1) |
| SB5 | **Adafruit 1477** — same button, blue (in hand) | AIR, front panel left hole, on the FlexiHAL `Aend` input; lamp H5 = valve energised (K4 14 via R5) |
| SB2 | **Adafruit 1441** — same button, yellow ==(to order)== | FEED HOLD, top-panel box, on the FlexiHAL `Pause` input; lamp H2 from `Aux1` via R2 |
| SB4 | **Adafruit 1440** — same button, green (in hand) | CYCLE START, top-panel box, on the FlexiHAL `Start` input; lamp H4 from `Aux2` via R4 |
| SB0 | **GCX1131** operator + 2× **ECX1030** NC + **ECX1651** legend plate (laser-cell stock) | E-stop, 2 NC; the BOM's 1NO1NC McMaster head becomes a spare |
| R1 R2 R4 R5 | 4× **4.7 kΩ ¼ W** resistors (plus 2.2 kΩ ½ W in case the lamps want more), heat-shrink | One in series with each button LED on 24 V; the Adafruit LEDs are bare |
| — | Printed two-button box / top plate for the top panel ==(CAD in progress)==; a Ø10 hole plug for the front panel's middle hole | Carries SB4 and SB2 on a face leaning back 30°; the plate version also moves the E-stop ≈10 mm toward the door |
| — | Printed DIN-rail mount for the H100 ==(Erik's CAD, in progress)==; lower rail cut to 330.5 mm | Hangs the VFD on the lower rail in place of two tapped holes and spacers ([[Voron Cascade Electronics Layout#The H100 on the lower rail]]) |
| — | Panel work: open the front-panel holes at d 40 and d 120 from Ø10 to Ø16 (the 15 mm flat is optional — it only stops the button turning); one new Ø12 cable hole in the top panel under the box (about a 62, d 60) | The three GCX buttons (GCX1202 / 1201 / 1203-24L) are not needed; the two red Adafruit buttons stay spare |
| SQ1–3 | PL-08N**2** (NC) rather than PL-08N (NO) | FlexiHAL and grblHAL conventions expect NPN NC; fail-safe. ==Check which variant arrived== |
| — | 3 × 2×4 IDC sockets + 8-way ribbon (already covered in [[Electronics#Cabling (FlexiHAL header → driver)]]) | FlexiHAL → CL57Y |
| — | ~4 m 14 AWG, 12 AWG green/yellow MTW for the bonds plus a high-strand 12 AWG length for the gantry run ==(to order; measure the runs)==, 4-core shielded 18 AWG (spindle), ferrules including 2 × 0.5 and 2 × 1.0 mm² twin; panel wire (MTW) from stock: 14 AWG black / white / green-yellow, 18 AWG blue and white-blue, 20 AWG blue; on order: 18 AWG black and white | BOM quantities are nominal |
| — | `flexihal_DIN_mount_pair` is already in the Cascade STLs; `pi_mount_2020`, all three Wago mounts and the LRS-350 saddle mounts are **not** needed (Pi on the FlexiHAL header, NDR-480 on the rail, terminals on DIN blocks) | |
# Configuration
Every setting this design depends on is in [[Voron Cascade Electrical Configuration]]: the supply trimmers, the CL57Y DIP switches, the FlexiHAL jumpers, the Remora pin map, the HAL and INI, vfdmod and the H100's keypad parameters, the post-processor and the Pi. What the panel needs from it before power goes on:
- **Supplies, trimmed with nothing connected:** SDR 24.0 V and never above, NDR 48.0 V, MDR about 5.15 V measured at the Pi under load.
- **CL57Y:** logic selector at 5 V, SW3 OFF (closed loop), SW5–8 ON OFF ON ON (1600 pulses/rev, so 400 steps/mm on the 4 mm-lead SFU1204 at 1:1); MF and ALM unconnected.
- **FlexiHAL:** isolation-bypass headers not fitted, P17 on the main 24 V input, the HALT XOR jumper in the non-default position, and the sensors on the board's own 12 V `V` pin, never on 24 V.
- ==**Aux pull-ups R56, R77, R81 and R82: to be removed before anything is wired** (decided 2026-11-14, review HW-01). With an output on at 24 V each would dissipate 0.58 W in a 0.1 W part. Which parts they are and the check afterwards are in [[Voron Cascade Bench Checks]]; no Aux output may be switched on at 24 V before that.==
- ==**Input series resistors (review HW-04, open).** By the schematic, a contact held closed puts about 117 mW in a 0.1 W resistor. That applies to Bend, closed whenever KM1 is out, and to Door, closed whenever a door is open; HALT has a circuit of its own (review R3-07). The check is the item marked "Do this first" in [[Voron Cascade Bench Checks]]. No fix is chosen.==
- **H100:** run and frequency commands over Modbus, from the Pi's UART 2 through the FlexiHAL's RS485 port, so no USB adapter. ==The register map and serial settings are still to be settled on the bench, and the motor-current limit, the stop mode (ramp, not coast: the door stop relies on it) and the restart parameters wait for the unit's manual.==
## FlexiHAL terminal names
Checked on Erik's A7 board, 2026-11-14 (review HW-07). This note uses the names on Expatria's `Pinout.png`: `Aend`, `Bend`, `Pause`, `Start`. The board's own silkscreen reads `X`, `Y`, `Z`, `M3`, `M4`, `DOOR`, `HALT`, `FD/HLD`, `CYC/ST` along the same row, so `Aend` = `M3`, `Bend` = `M4`, `Pause` = `FD/HLD` and `Start` = `CYC/ST`. (`X`, `Y`, `Z`, `M3`, `DOOR` and `CYC/ST` were read from photos of the board; the other three labels sit behind the connectors.) The back of the board prints `12V SIG GND` at every input block. Seen from the top with the inputs along the upper edge, that is G, S, V from left to right, as `Pinout.png` draws it, with V the pin nearest the Aux terminals.
# Decisions
Newest first. An entry that opens in italics has since been reversed or replaced, or only names a revision letter, and is cut to a few lines here. Its full text, with every other entry as it stood on 2026-11-16, is in [[Voron Cascade Electronics Wiring History]].
## 2026-11-15: One grounding block on the rear rail, at block 11 (Layout J)
Erik's call: two rail-bonding blocks on the rear rail are one more than the job needs. One 7641K81 goes back to stock and a plain green 7641K51 takes its place, and the remaining grounding block moves from the left-hand end of the PE group to the right-hand end. The group is now blocks 5–10 green, jumpered, and block 11 the 7641K81, linked to block 10 by a 12 AWG wire because the jumper bar still does not fit it. The row is still 15 blocks and nothing moves. What lands where follows from that, and it is this note's allocation, not part of Erik's instruction: the incoming earth, the plate stud, the frame lug and every device earth land on the six green blocks, one conductor per screw, so they meet on the jumper bar and none of them depends on the wire link. The link only bonds the rail, and the spare screw is the second one on block 11. Two wires change blocks: the lower-rail feed goes to block 6 and the gantry jumper to block 7. This reverses the decision of 2026-11-13 below, and is the alternative that entry names. ==It needs one jumper bar that spans the six green blocks.== The layout is at J for it and now has its own note, [[Voron Cascade Electronics Layout]]; the wiring stays at Rev O.
## 2026-11-15: Rev O
*Letter only.* Rev O is Rev N as the third review saw it, plus the three entries of this date: the door change, the accepted limit and the review's corrections. Not reviewed; the bench is next.
## 2026-11-15: The door acts through LinuxCNC only
Erik's decision, after the third review. What he wants from the door switches is a stop when the door is opened while the machine is cutting. With the spindle off he wants to jog the axes and touch off with a 3D probe with the door open, which the hardware door channel did not allow. So the door relay's contact comes out of KM1's coil circuit: KM1 A2 moves from K5 14 to K5 A2, the 0 V side, and K5 stays as the relay that reads the two switches and drives the DOOR input. LinuxCNC does the rest. Door open with the spindle commanded on, which includes a spindle start with the door already open: the VFD's run command drops, the feed stops, the program is aborted and the spindle command cleared; the machine stays on, drive power stays up and the axes stay homed; nothing restarts when the door shuts. If the spindle is still commanded on 1 s later, the E-stop latch trips as a backup. Door open with the spindle off: nothing happens. The alternatives were a hardware cut of the spindle alone, which needs more parts and wiring, and leaving the door as it was. **What it gives up:** the door no longer removes drive power or the valve's feed in hardware; the stop depends on LinuxCNC, the Pi, the SPI link, the DOOR input and Modbus; and the axes are live with the door open. The door was already described as a convenience interlock and not a safety function (S2), and it is now a narrower one. In the simulator the door test passes 23 of 23 and the scripted run 82 of 82 ([[Voron Cascade Electrical Configuration#Simulator run (2026-11-13)]]). Not reviewed, and not run on the machine. ==For the bench: DOOR polarity, how long the spindle takes to stop, the VFD's stop mode, the backup, and whether QtDragon's own HAL files clash with the three pins the door uses ([[Voron Cascade Bench Checks]], part C).== This change is what made the revision Rev O (entry above).
## 2026-11-15: Third review: one accepted limit, corrections, and the bench next
The third independent review, of the Rev N package of 2026-11-14 (`Cascade-Electrical-Review-RevN-v2`), did not pass it. Of the second review's six findings it closed one (N04), closed three with a problem (N02, N03, N05) and left two open (N01, its blocker, and N06). Of the first review's 25 findings that were still open it closed one (HW-06), closed three with a problem (S4, SW-05, SW-06) and left 21 open, nearly all of them waiting for the bench or for parts. It added two blockers (R3-01, R3-02), two majors (R3-03, R3-04) and four minors (R3-05 to R3-08). Like both earlier reviews it found the hardware E-stop channel intact: the E-stop button cuts drive power whatever the software does.
All three blockers sit under one fault: a FlexiHAL that answers the Pi's reads but ignores its commands. Both new ones were reproduced in the simulator before anything was decided. R3-01: every click on the screen's E-stop reset restarts the SPI link for 0.75 s, refused or not, so clicks a second apart or less keep the board's watchdog quiet and K2 on. R3-02: until the board lets K2 go, about 1.3 s after a trip, anything that restores KM1's coil circuit brings drive power back. The statement made here on 2026-11-14 that KM1 stayed out in 15 of 15 such trips came from a script that looked only at the end of each run, and is withdrawn. Erik's decisions:
1. **The fault is an accepted limit.** Nobody has named a way it can happen; the present link arrangement is the fourth, and each of the last three had a hole found within a day. The HAL's link logic stays as it is. If the board stops taking commands, the E-stop button is the stop. The link stop and the firmware's timeout are a backstop that acts about 1.3 s after a trip, and only if nobody clicks reset in that time. The reviewer's position is that N01 is not closed. Two further patches were weighed and not made: a lockout that keeps the link off for longer than the firmware's timeout after a trip (every reset refused for about 2 s on a healthy machine, and the KM1 window stays), and a following error tripping the latch (it broke the first reset when tried).
2. **The door.** The review's other design question led to the entry above.
3. **Corrections, with no design change.** The withdrawn claims ("KM1 stayed out, 15 of 15", "cannot come back by itself", "every trip ends with the outputs off about 1.3 s later"). The reset check is described as what it detects, a status contact reading "in", and not as a weld detector (R3-03). The simulator's latency figure is withdrawn and its "every output off" assertion widened to all ten outputs (R3-04, R3-05). Quick double presses are described as they are: two AIR presses both act, and only a quick second CYCLE START can be lost (R3-06). HALT has its own input circuit, so the 117 mW figure is not its (R3-07). Stale lines in Layout I and the cable schedule (R3-08). And three of this note's own errors that the reviewer caught in passing: a 240 V feed is no fix for a 110 V-input VFD; KM1's DC coil is 6 W in the data sheet's table where this note assumed 9 W; and the gates before wiring are more than two.
4. **The bench is next, not a fourth paper review.** The review's own list shows that what is left is bench work: the Aux rework, then the powered checks on the FlexiHAL alone, where the firmware's real timeout and reset behaviour can be measured. Parked for that phase: the firmware's separate reset input from the Pi (`flexi.PRU-reset`), which might give a way to switch the board off that does not depend on the board taking a command.
Still open and unchanged: the list at the end of the second review's entry below. The door change has had no independent review.
## 2026-11-14: The SPI link follows the E-stop latch
Found while writing the response for the next review. The afternoon's fix for the second review's blocker (N01) stopped the SPI link 0.5 s after LinuxCNC's own E-stop, by tying it to `iocontrol.0.user-enable-out`. LinuxCNC leaves that signal on when the E-stop comes from outside, so after a door trip, an E-stop-button trip or KM1 dropping out the link never stopped. In the simulator, with the board taking no commands, K2 then stayed on at the board and the board kept stepping; shutting the door, or POWER ON after the E-stop button, brought KM1 back in with the axis running and LinuxCNC in E-stop (9 of 9). Erik approved the change: the link runs while the E-stop latch is OK and for 0.5 s after it trips, whatever tripped it, and a reset click on the screen starts it again. The same trips then end with the board's outputs off 1.21 to 1.30 s later and KM1 staying out (15 of 15: **withdrawn 2026-11-15**, because the script looked only at the end of each run; see the third review's entry above), and the scripted run passed 72 of 72 ([[Voron Cascade Electrical Configuration#Simulator run (2026-11-13)]]). Nothing in the wiring changes. **Not covered:** a board that stops taking commands when nothing trips. A feed hold then does not reach it; LinuxCNC reports a following error and goes to machine-off, and the axis runs on with the drives powered until an E-stop is pressed. No ordinary fault is known that stops commands and leaves the board answering, so this is a missing backstop, as N01 was. Tripping the latch on a following error was tried and made the first reset after such a stop fail, so it was left out. A side effect: after any trip, not only the on-screen E-stop, `halshow` shows the inputs' last values until the next reset.
## 2026-11-14: The 48 V −V bond stays 18 AWG
Erik accepted this as a deviation from the 12 AWG bonding rule, after the second review pointed out that the bonding table and the wire labels disagreed (EL03, D1). The one 48 V −V → PE bond is 18 AWG white/blue, in a 2 × 1.0 mm² twin ferrule with U4's −V feed on the NDR's second −V terminal, and lands on the lower-rail grounding block: what the wire labels already had. Its job is to tie the 48 V rail to earth. A short from the 48 V rail to the chassis returns through it, and the NDR limits that to 10.5–13 A and shuts down after about 3 s, which 18 AWG carries. What the deviation gives up: the bond is not sized to carry a mains fault onto the 48 V wiring until the branch breaker clears, which is what the 12 AWG rule is for. The 18 AWG driver feeds are no heavier. The alternative was a 12 AWG bond on a terminal of its own, which the NDR's two −V screws leave no room for without a distribution block. The 24 V 0 V bond is not affected: it has an XT3 screw to itself. ==Still to check: that the twin ferrule seats in the NDR's terminals ([[Voron Cascade Bench Checks]]).==
## 2026-11-14: Second review: three HAL changes, and what stays open
The second independent review, of Rev N, did not pass it. Of the first review's 45 findings it counted 20 closed, 3 closed with a problem and 22 not closed: 13 of the 22 wait for the bench or for parts, as this note already said, 7 were statements in the notes or drawings that were wrong or claimed too much, and 2 were questions of design. It added one blocker and five majors, most of them about how much the simulator run had really shown. Erik approved all five proposals the same day.
1. **The link stops 0.5 s after LinuxCNC's own E-stop (N01).** With the link kept up for good, a board that stopped taking writes while still answering reads would have held K2 and the last step frequency indefinitely, because the firmware's watchdog counts reads. The firmware's timeout is the backstop again. As approved it followed LinuxCNC's enable output, which covers only the on-screen E-stop; corrected that evening (see "The SPI link follows the E-stop latch" above).
2. **KM1 dropping out trips the E-stop latch (S5, N02).** A dip in the 24 V that drops KM1 but not K3 can no longer bring drive power back by itself, and a short dropout cannot slip past the un-home line. (2026-11-15: true as long as the board takes the command that opens K2; review R3-02.)
3. **The latch cannot be reset while KM1's status contact reads "in" (EL07).** A dead contact or wire, or a welded KM1 or K2, now shows up as a refused reset. (2026-11-15: what it shows is a status contact reading "in". It is not a weld detector; review R3-03.) The alternative was to accept the contact's limits as they stood.
4. **Two presses of one button less than 0.25 s apart count as one (N06).** Documented, not changed. (2026-11-15: that holds only for a second CYCLE START. Two quick AIR presses both act; review R3-06.)
5. **Corrections.** The simulator scripts and board model, and the statements the review quoted from the notes and drawings.
The simulator was rerun on the HAL built from the Configuration note ([[Voron Cascade Electrical Configuration#Simulator run (2026-11-13)]]). Not changed, and still open: the mains budget (EL01), the bonding sizes (EL03; the 48 V −V bond was accepted as it is later the same day, entry above), the inlet (EL04), contactor duty (EL05), the status contact's rating (EL07: now detected, not cured), fuse and contact coordination (EL08), the unrated button contact (EL09), the FlexiHAL's input resistors (HW-04) and the bench items. The three HAL changes have had no independent review.
## 2026-11-14: H100 on the lower rail, on a printed DIN mount
Erik's call, made after the Rev N review bundle was cut: the lower rail runs on under the VFD to a 352, and the H100 hangs on it on a printed mount he is designing, instead of on two M5 screws tapped into the plate with 5 mm spacers. Layout I had drawn this as an option. The VFD's body stays where it was (a 257–347, h 55.6–205.6), so nothing around it moves; it stands 7.5 mm plus the mount's thickness off the plate, which leaves 42 mm less that thickness to the door. The rail becomes one 330.5 mm piece with a fourth screw, H4, at a 340 on the gantry upright's T-slot. What goes away: the two tapped VFD holes (one of which had to thread between two M8 bolt heads), the spacers, the VFD marking jig, and the second earth path through the lower-left bolt, so the VFD's PE terminal wire is now its only earth. The alternative was to stay with the bolted mounting of 2026-11-13.
## 2026-11-14: Rev N
*Letter only.* Rev N collected what was decided, measured and cut between Rev M (2026-11-12) and the second independent review. Each item has its own entry.
## 2026-11-14: Remove the FlexiHAL's Aux pull-up resistors (review HW-01)
Measured on Erik's board (PCB revision A7), unpowered: `Aux +` to `Aux −` reads 1.00 kΩ on all four Aux outputs and open on Mist, and R81 and R82 are marked `01B`, the 1 % code for 1.00 kΩ. That is the published A7 schematic: R56, R77, R81 and R82 run from the Aux supply to each output, in parallel with the load, and with an output on at 24 V each dissipates 0.58 W in a 0.1 W part. K2 on Aux0 is on whenever the machine is out of E-stop. Erik's call: remove the four resistors. The Aux drivers then match the Mist, Flood and Spindle drivers, which use the same FET and diode with no parallel resistor, and the wiring, the drawings and the HAL stay as they are. The alternative needed no soldering: K2 on the Flood output and the two lamps on Aux at 5 V (P17 moved, lamp resistors about 330 Ω), with the HAL's latch output moved from `AUX0` to `COOLANT`. Wiring stays on hold until the rework is done and all four outputs read open.
## 2026-11-13: The SPI link stays up through an on-screen E-stop
*Replaced 2026-11-14.* The link was tied up for good, so that K2's command and the stop reach the board in the same servo cycle. With it up for good nothing dropped K2 if the board stopped taking commands, so the link now follows the E-stop latch (entry above).
## 2026-11-13: Un-home on loss of drive power
The simulator run of the Rev M HAL showed that LinuxCNC often left the axes marked homed after a door or E-stop-button trip, and always when KM1 dropped by itself, although the drives had lost power every time. LinuxCNC un-homes `VOLATILE_HOME` joints only when it runs its own E-stop or machine-off, and a hardware trip usually disables motion through `motion.enable` first. Erik approved one more HAL line: KM1's status contact, not inverted, drives `halui.joint.N.unhome` for all three joints (`power-lost`). In the simulator that un-homed the axes in 30 of 30 trips. The alternative was a written rule to re-home after every trip. The line needs no wiring, but it hangs on the same contact as the machine-on gate: a broken wire in the Bend pair reads as power present and defeats both (rung 6). **Added 2026-11-14:** the un-home line alone could miss a dropout shorter than halui's 20 ms poll, so KM1 dropping out now trips the E-stop latch as well, and a Bend pair that reads "in" with K2 open blocks the reset (second review, N02 and EL07; see the 2026-11-14 entry).
## 2026-11-13: Lower-rail grounding block, drivers at 31 mm pitch
The lower plate rail gets its own 7641K81 at a 248–254, between the SDR and the VFD, and the three drivers sit at 31 mm pitch instead of 33 to make room for it, as Layout I draws them. The 48 V −V bond lands on that block. The alternative was to keep the 33 mm pitch, bond the rail through its masked footprint with a paint-piercing washer under one rail screw, and put the −V bond on the PE group's spare screw. Erik's call: the grounding block is fine. It gives the rail and the −V bond a screw terminal that can be seen and metered, for 2 mm of driver pitch.
## 2026-11-13: VFD 5 mm lower (bolt head behind its upper mounting hole)
*Partly replaced 2026-11-14.* The VFD's body went 5 mm lower, to h 55.6–205.6, to clear an M8 bolt head behind its upper mounting hole. The height stands; the two tapped holes it was for went away with the rail mount.
## 2026-11-13: No DC branch fuses; F1 and F2 stay as they are (review EL11, EL08)
The review asked for short-circuit protection on the small DC branches (EL11): the two USB-C leads on the 5 V supply, the fan and light on the 24 V, and the three 18 AWG driver feeds on the 48 V. Erik decided to fit none of them: not necessary for a hobby machine. Each branch relies on its supply's own limit, as in the UEB design. What that leaves is set out under [[#What stays on, what gets switched]]: the 48 V and 24 V supplies shut down within about 3 s of a short and the 5 V supply does not, so its USB-C pigtails are the least protected wires in the bay. The option that was turned down was three inline blade-fuse holders (Pi, display, fan + light) with none on the 48 V; a third fuse terminal on the upper rail would also have needed KM1 moved back 6 mm.
F1 and F2 stay 1 A time-delay fuses from stock (EL08). The review is right that such a fuse does not hold a fault to 1 A, so the claim that F1 keeps the K3 contact inside its 1 A DC-13 rating is withdrawn: the fuses protect the branch wiring, and the 6 A relay contacts carry the fault for the moment it takes the fuse to clear. One check goes to [[Voron Cascade Bench Checks]]: with the latch set, an open F1 must drop K3, because the fuse terminal's blown-fuse LED passes about 2 mA around an open fuse.
## 2026-11-13: Layout I, and the lower-rail holes re-spaced
*Replaced by Layout J and the fourth rail screw.* Layout I took over from Layout H as the bay placement, and the lower-rail screws went to 100 mm spacing (a 40 / 140 / 240) so that they land on a rail slotted at 25 mm. They are now at a 40 / 140 / 240 / 340, and the placement is [[Voron Cascade Electronics Layout]].
## 2026-11-13: Second grounding block on the rear rail
*Reversed 2026-11-15.* A fourth 7641K81 went in as block 6 when the rail turned out to have room for fifteen blocks. Erik took the other choice two days later: one grounding block, at block 11 (entry above). The fifteen-block row and XT2 at 12–15 stand.
## 2026-11-12: PE group linked by wire (review EL02)
*Block numbers replaced 2026-11-13 and 2026-11-15.* Erik tried the part: the 7641K51 jumper bar does not seat in the 7641K81 grounding block, so the grounding block is linked to the jumpered green blocks by a 12 AWG wire. That stands; the link now runs from block 10 to block 11.
## 2026-11-12: Rev M — review fixes and accepted limits
Erik approved these after the independent review of Rev L. **Fixed:** K2 follows the E-stop latch, so a door or HALT trip keeps drive power off until the screen reset (S1). The valve's feed runs through KM1's NO aux contact, so every hardware trip closes the valve (S4); the status signal moves to the NC aux and gates machine-on through `motion.enable` (SW-03). CYCLE START and AIR act once per fresh, debounced press; the HAL line that would not load is gone; the E-stop latch runs after its inputs are read (SW-06, SW-04, SW-11). Bonding conductors go from 14 to 12 AWG, sized for the 20 A branch breaker (EL03).
**Accepted as they are, for a personal desktop mill with one operator:** the single-relay door channel, described as a convenience interlock (S2); a held or welded POWER ON button re-arming the hardware latch (S5); no hardware OFF other than the E-stop button and the breaker (S6); driver alarms left unwired until after the first cuts (HW-06). Access after a stop is a written rule (S3, next entry).
**Alternatives for the valve interlock:** KM1's spare main pole (its terminals start at 16 AWG, and it would put a 24 V circuit between the line and neutral poles), or an add-on auxiliary block (not checked against Layout H's clearances). Using the built-in NO pair is free, but it moves the status signal to the NC pair, where a broken wire reads as power present.
## 2026-11-12: Access after a stop is a written rule (review S3)
The review's S3 is that dropping the contactor does not make the enclosure safe to reach into: the spindle coasts, Z can sink with no holding torque, and nothing locks the door. This is a personal desktop mill with one operator, so a written rule covers it, and no door lock, spindle brake or Z brake is added. The rule sits with the other consequences under the E-stop chain; the coast-down time and the Z sink still have to be measured and written into it.
## 2026-11-12: Panel wire from the shelf, no single wire thinner than 20 AWG
The single wires that were 24 AWG (the FlexiHAL's relay-coil and input pairs, HALT, DOOR, the door switches, the front-panel lamps and AIR, the tool setter) are now 20 AWG blue for every + and S conductor and 18 AWG white/blue for every 0 V, G and −. That is the MTW on hand, along with 18 AWG blue and 14 AWG black, white and green/yellow. 24 AWG had been picked for the small terminals, but nothing needed it: the plugs for the FlexiHAL's 3.5 mm headers are listed for 28–16 AWG, and the review (EL10) pointed out that several of those wires land on XT3 blocks whose range starts at 22 AWG. The wires that land on KM1 are 18 AWG blue. The jacketed cables (sensor leads, RS485, the top-box multicore) are unchanged, and 18 AWG black for the 48 V + runs was ordered the same day, together with 18 AWG white.
## 2026-11-11: Rev L — no POWER OFF, 16 mm buttons, cycle start and AIR
Layout H's button problem (the 66 mm GCX stacks don't fit behind the front panel) turned into a review of what each control is for. The red POWER OFF button had NC contacts in both the latch chain and the HALT loop, which makes it a second E-stop that doesn't latch; with the E-stop for emergencies and the on-screen E-stop for the routine case (it drops K2, and K2 drops KM1) it had no job left, and neither did the red "power off" lamp. The Millennium UEB, which this design ports, has only a rocker and an E-stop and does its whole power latch in software; keeping a hardware **on** and letting software do the **off** keeps the property that matters — nothing software does can restore power past an open E-stop or door. Dropping the button also removed the only NC contact the small buttons couldn't provide, so the controls could become the Adafruit 16 mm illuminated momentaries already in hand: POWER ON (white) and AIR (blue) in the front panel's outer holes, the middle hole plugged until AUX has a function, and FEED HOLD (yellow) with a new CYCLE START (green) in a printed two-button box on the top panel — the two controls worth a tactile button mid-cut. CYCLE START is resume-only to begin with and its lamp flashes while paused; FEED HOLD only pauses; AIR toggles the mist output through LinuxCNC so the button and M7 / M9 share one state. White rather than green for POWER ON, so green means only "running / press to resume". Considered and dropped: IDEC LB-series 16 mm buttons (round, 24 V LED, 2 CO — they would have supplied the NC contact, but stock was thin and the button they were for went away), a three-button top box with POWER ON on top, and an AIR switch wired straight to the valve. The E-stop stays a GCX1131 in the top panel; a printed top plate that carries the box and moves the E-stop about 10 mm toward the door is being drawn.
## 2026-11-10: Rev K — McMaster 7641K51 blocks everywhere, colours, Layout H
Konnect-It blocks lasted one revision: there is a stock of McMaster 7641K51 (TE, 6 mm, choose-a-colour) on hand, so XT1, XT2, PE and XT3 are all 7641K51, and only F1/F2 stay Konnect-It fuse terminals. Colour scheme chosen by conductor class rather than circuit: black = un-switched line, red = KM1-switched line, white = every grounded conductor (N, N-SAFE, 24 V 0 V), green = PE, blue = +24 V, gray = labelled 24 V control nets; beige / orange / yellow unused. Placement now follows the main Cascade agent's Layout H: XT1 / PE / XT2 on a rear-panel rail (13 blocks), and K2–K5 + F1 F2 + XT3 in the ≈121 mm gap on the upper rail between the relays and KM1 — which is why XT3 is trimmed to 12 blocks with a few doubled conductors at the buttons and relays. Drawing 3 is no longer a bay layout (that is Layout H's job) but a terminal-strip drawing, `media/cascade-terminals.svg`.
## 2026-11-10: Rev J — Konnect-It terminal strip for XT3, and a door relay
*Partly replaced.* XT3 became a screw-terminal strip with a block-by-block table: a Konnect-It KN-T12, replaced by 7641K51 blocks in Rev K. K5 came in as the door relay, because a KW10 has one common and cannot sit in a 24 V rung and across a FlexiHAL input at once. K5 stands; its NO contact left KM1's coil circuit on 2026-11-15.
## 2026-11-10: Rev I — 22 mm illuminated GCX buttons
*Replaced by Rev L.* 22 mm GCX illuminated operators for the front panel. Their 66 mm stacks did not fit behind it, and Rev L went to 16 mm buttons. What stands: the GCX1131 E-stop with two NC contacts, and HALT as an NC loop with the XOR jumper in the non-default position.
## 2026-11-10: Rev H — air-blast valve on the Mist output
A third 52003 (K4) driven by the FlexiHAL `Mist` output switches a 24 VDC 2/2 NC air valve (Y1) through F2, so M7/M9 in G-code control a chip-clearing air blast. Chosen over driving the valve directly from the FlexiHAL because a 10 W valve coil exceeds the output's 250 mA limit. `Flood` stays free for a coolant pump and the Lovato contactor idea (vac auto-start) would hang off a fourth 52003 if ever wanted.
## 2026-11-10: Rev G — slimline interface relays
K2 and K3 are Murrelektronik 52003s from the laser-cell stock instead of the AutomationDirect ice-cube relays: 6.2 mm each on the rail, 1 CO rated 1 A DC-13 at 24 V (the KM1 coil is 0.38 A), 24 V AC/DC rectified input (no diode, and the FlexiHAL output sees 17 mA). Because the 52003 has a single contact, rung 3 is fed from the latch node (node L, between the seal-in and the K3 coil) rather than through a second K3 contact — same logic, one contact per relay. The two spare poles the ice cubes offered are gone; a future vac auto-start gets its own 52003.
## 2026-11-09: Rev E/F — 5 V supply
*Rev E replaced by Rev F the same evening.* The 5 V rail feeds only the Pi 5 and the display, and the FlexiHAL cannot source it. Rev E's DDR-60G-5 DC-DC was a week out, so PSU3 is the mains-fed MDR-60-5 (McMaster 3718N152), which stands. The other supplies weighed are in the history note.
## 2026-11-09: Rev D — drawn to the hardware in hand
The first drafts assumed the BOM's open-loop LDO motors with DM542T drivers, an LRS-350-48 and IRM supplies. The vault's [[Electronics]] note already records the real kit: StepperOnline 3-CLYS30-V20 closed-loop drivers and 5 A encoder motors, NDR-480-48, Delta 20DRGS5 line filter, HDR-30-5, uFlexiNET. Drawings and this note now match it; the DM542T ENA/ALM workarounds are gone (CL57Y MF stays open, ALM polarity already suits the FlexiHAL).
## 2026-11-08: Rev C — hardware START/STOP latch and door in the contactor chain
*Partly reversed.* Adopted from a friend's working Cascade: a latching relay K3 in series with the LinuxCNC-enable relay K2, and both door switches ahead of the KM1 coil. The latch stands, without its STOP button since Rev L; the door left the chain on 2026-11-15.
## 2026-11-08: Rev B — IronHorse 24 VDC contactor and SDR-120-24
Swap the BOM's 120 V-coil WEG contactor (already ordered; now spare) for an IronHorse HMC-18B30-11-DS (24 VDC coil, built-in 1NO/1NC aux, HMX1-SSVRC-DC suppressor) and the owned HDR-30-24 for a Mean Well SDR-120-24. The whole control chain is 24 V, the power-present status comes off the contactor's own aux contact, and the 24 V rail has headroom. F1's holder and fuse come from the laser-cell Konnect-It stock.
## 2026-11-08: FlexiHAL + Remora/LinuxCNC instead of BTT Scylla
Controller is the Expatria FlexiHAL, not the Scylla. Stack is LinuxCNC via Remora with the Pi on the FlexiHAL GPIO header. The planned USB-RS485 adapter is dropped: Expatria's sample config drives the board's own RS485 from the Pi UART, and an H100 vfdmod config already exists.
## 2026-11-08: UEB architecture, Cascade parts, electronics inside the bay
Port the UEB's un-switched / contactor-switched split onto the Cascade hardware rather than building a separate box.
## 2026-11-08: E-stop scope
E-stop drops the 48 V motor rail and the VFD mains through KM1; 24 V, 5 V, FlexiHAL and Pi stay up.
## 2026-11-08: Mains
110 V H100 kit on a 120 V / 20 A circuit with a NEMA 5-20P cord. Breaker (15 A) and inlet (16 A) are the limiting elements, so the VFD current limit caps spindle power rather than relying on Q1.
# TODO
- ==Three reviews, none passed. The HAL changes made since the second review and the door change of 2026-11-15 have not been reviewed, and nothing has run on the board. By Erik's decision the next step is the bench, not another paper review. The open findings are listed in [[#Decisions]] and in [[Voron Cascade Bench Checks]].==
- ==Door change (2026-11-15), when wiring: KM1 A2 lands on K5 A2, in a twin ferrule with the A2 → 11 link, and not on K5 14, which stays empty. The wire is 18 AWG white-blue, number `24N`.==
- ==Rear-rail PE group (2026-11-15), when wiring: blocks 5–10 green on one jumper bar that spans six, the 7641K81 at block 11, and a 12 AWG link from block 10 to block 11. The incoming earth goes on a green block, not on the grounding block.==
- ==FlexiHAL rework, gates wiring: remove R56, R77, R81 and R82 (the Aux pull-ups), then check that `Aux +` to `Aux −` reads open on all four and that R70, R66, R76 and R73 still read about 1 kΩ ([[Voron Cascade Bench Checks]]).==
- ==Order: HMC-18B30-11-DS, HMX1-SSVRC-DC, DVD-2AC2A-24D valve + SC18-LS24-0 DIN plug (AutomationDirect); SDR-120-24 (DigiKey); one Adafruit 1441 yellow 16 mm pushbutton, 4.7 kΩ ¼ W and 2.2 kΩ ½ W resistors; any 7641K51 colours, jumper bars, end stops / covers the stock is short of (McMaster); 12 AWG green/yellow MTW, a high-strand 12 AWG green/yellow length for the gantry, and ring lugs to suit. Pull four 52003 relays, two KN-F10L24DC fuse terminals, two 1 A fuses, the GCX1131 + 2× ECX1030 + ECX1651 from the laser stock and re-order them for the laser. The three GCX buttons (GCX1202 / 1201 / 1203-24L) are no longer needed.==
- ==Bonding: before powder coating, mask the stud pad (a 366, h 120.5), the two plate rail footprints (upper a 24–398 / h 239.5–274.5, lower a 21.5–352 / h 84.5–119.5) — the rear rail is on the back panel, not the plate; fit the 7641K81s and the plate / frame / gantry lugs; meter ≤ 0.1 Ω from the inlet PE pin to every point in the Grounding table (bed, base frame, far corners, X and Z carriages, spindle body included) before first power-up.==
- ==Lower rail: measure the rail's slot pitch, cut the rail to 330.5 mm, print the marking jig and drill and tap the four M5 holes at a 40 / 140 / 240 / 340, h 102 ([[Voron Cascade Electronics Layout#Drill and tap list]]; the hole at a 340 runs into the upright's T-slot: drill stop, short screw); plug the driver holes that open into the machining area.==
- ==VFD: measure the H100's hole pattern, body and back face, then design and print the DIN-rail mount to [[Voron Cascade Electronics Layout#The H100 on the lower rail]] (set the numbers in `media/cascade-vfd-rail-mount-ref.py` if the unit differs from 77 × 137 and 90 × 150 × 110) and put the mount's real thickness into the layout note, which draws 6 mm. Mark the bonding stud by measurement: 34 mm from the right post, 100.5 mm above the bottom extrusion.==
- ==Measure the end cover of the upper-rail group (the K4 → KM1 gap is 119.4 mm and the group 112 to 113 mm with the 8 mm end stops); KM1 can still slide back about 6 mm.==
- ==Prove the HAL on the bench: un-homing on loss of drive power, the link stopping 0.5 s after a trip, and KM1 dropping out tripping the latch ([[Voron Cascade Bench Checks]], parts A, B and C).==
- ==Draw and print the top plate / two-button box (30 mm pitch, face leaning back 30°, E-stop ≈10 mm toward the door, Ø12 cable hole under the box); open the front-panel holes at d 40 and d 120 to Ø16 and plug d 80.==
- ==Bench-check the button LEDs on 24 V through 4.7 kΩ: polarity, brightness, and that an Aux output that is off leaves its lamp fully dark. Bench-check POWER ON making K3 with K2 already closed (it then carries KM1's coil until K3 seals).==
- ==AUX (middle front hole) is plugged: give it a function, an input and a lamp output (`Aux3` is free) when there is one.==
- ==KM1 sits in the air stream to the fan with its front corner 13.6 mm above the VFD's top and is rated to 40 °C ambient — check the temperature there after the first long spindle run.==
- ==Air side: regulator/filter and Y1 outside the cabinet, 4 mm OD tubing through the 10×20 drag chain (6 mm needs the 15×15), nozzle on the spindle clamp.==
- ==The spindle's nameplate and the H100 manual's parameter pages are still to come (the VFD's plate is in: `H100-1.5C2-1B`, 110 V single-phase in, 0–110 V 12.5 A out).==
- ==Bench-verify the H100 register map and serial settings against the Expatria vfdmod ini ([[Voron Cascade Electrical Configuration#Spindle — vfdmod and the H100]]), then set F163–F165.==
- ==Set the SDR-120-24 to 24.0 V and the NDR-480-48 to 48.0 V before the FlexiHAL / drivers are connected; trim the MDR-60-5 to ~5.15 V at the Pi under load.==
- ==Wire the KW10 door switches COM + NO only (two leads each): SQ5 COM → XT3:4, SQ5 NO → XT3:7, SQ6 COM → XT3:7, SQ6 NO → K5 A1; tape the NC pins.==
- ==Bench-test rungs 1–7 on the DIN rail with a lamp in place of the NDR/VFD before wiring the bay: POWER ON with the E-stop in → nothing; release the E-stop → still nothing; POWER ON → K3 holds, node L goes live and the white lamp lights; E-stop → drops; on-screen E-stop with K3 latched → KM1 drops, the white lamp stays lit, the screen's E-stop reset restores; door open → K5 drops and DOOR asserts, and KM1 stays in; with K4 held on, each of the trips above still closes the valve.==
- ==Confirm the endstop sensors are the NC variant (PL-08N2) and 10–30 V rated.==
- ==Check GX16 pin 4 → spindle body continuity; bond at the Z clamp if open.==
- ==Rail stock: the lower rail is 330.5 mm (it runs on under the VFD), so with the 119 mm rear rail it cannot come from the BOM's 350 mm piece; the upper rail needs its own 375 mm piece as well, so a 1 m length covers both (Layout J).==
- ==Drag chain: one motor + encoder, one endstop, the PE jumper, later a 4 mm air line (≈49 % of a 10×20 with the 12 AWG jumper; the air line then rides on the encoder cable: Layout J) — caliper the kit cables, and record which axis it is and how the other motor/encoder cables and the spindle cable are carried.==
- ==Make the HAL and INI changes listed in [[Voron Cascade Electrical Configuration]] (keep, change, add); set `COORDINATES = XYZ` and `SCALE = 400` in each joint section.==
- ==Measure the Daylight bar current and mains current at full spindle speed under a real cut; adjust the H100 current limit so Q1 holds.==
- ==Wire the CL57Y ALM outputs to AL− after the first cuts (review HW-06: accepted unwired until then).==
- ==Label the bay: KM1 switched side, "E-stop does not stop spindle rotation instantly", and at the door "Door open: axes stay live".==
- ==Wire labels: print them from [[#Wire numbers and labels]] (about 85 conductors, two labels each, plus the cable jackets); check Q1, Z1 and VFD terminal markings first; put the wire numbers on drawings 1 and 3.==
# References
## Related notes
- [[Electronics]]: parts in hand, bench-jog wiring, CL57Y DIP tables, cable colours, grblHAL bench settings
- [[Voron Cascade BOM]]: the Cascade BOM with order status
- [[Voron Cascade Electronics Layout]] (Layout J, 2026-11-15): the authoritative bay placement, fit test, drill-and-tap list, panel views, the operator-control layout (front-panel buttons, two-button top box), the lower-rail marking jig and the reference for the VFD's rail mount. Layouts H and I were published pages, [Layout I](https://claude.ai/artifact/SMifPvbaUPLKZVGp382NJC) (2026-11-13) and [Layout H](https://claude.ai/artifact/6x97JWPPpbwiCHod5nkBEr) (revised 2026-11-11), which stay as the record of those two layouts
- [[Voron Cascade Electrical Configuration]]: every setting this design needs — jumpers, DIP, trims, HAL/INI, VFD, post-processor
- [[Industrial Control Panel Wire Size and Color Standards]], [[DIN Terminal Blocks]] and [[Dymo Heat Shrink Labels]]: the colour, identification and labelling conventions the wire list follows
- [[Voron Cascade Bench Checks]]: the bench checks and information the 2026-11-12 review calls for
- [[Voron Cascade Electronics Wiring History]]: every decision entry in full, including the ones since reversed, the completed TODO items and the full changelog up to 2026-11-16
- [[G-Penny H100 VFD Modbus Integration]]: H100 parameters and register map
- [[RepRapFirmware and MillenniumOS on BTT Scylla]] and [[Duet Web Control vs gSender]]: the earlier firmware comparison (superseded by the Remora/LinuxCNC decision)
## Sources
- Voron Cascade: [repo](https://github.com/VoronDesign/Voron-Cascade) · [manual PDF](https://github.com/VoronDesign/Voron-Cascade/raw/refs/heads/main/Manual/Cascade_Assembly_Manual.pdf) · [BOM xlsx](https://github.com/VoronDesign/Voron-Cascade/blob/main/CAD/Voron_Cascade_BOM.xlsx) · issues [#7](https://github.com/VoronDesign/Voron-Cascade/issues/7) [#9](https://github.com/VoronDesign/Voron-Cascade/issues/9) [#10](https://github.com/VoronDesign/Voron-Cascade/issues/10) (BOM errata: Wago 221-415, drag chain 10×20, side panel 390×302, missing T-nuts)
- Millennium Machines UEB: [repo](https://github.com/MillenniumMachines/Universal-Electronics-Box) · [docs](https://millenniummachines.github.io/docs/ueb/) · [sourcing guide](https://millenniummachines.github.io/docs/ueb/bom/sourcing_guide/)
- Expatria: [Flexi-HAL](https://github.com/Expatria-Technologies/Flexi-HAL) · [remora-flexi-hal](https://github.com/Expatria-Technologies/remora-flexi-hal) · [Flexi-Pi](https://github.com/Expatria-Technologies/Flexi-Pi) · [Mods & accessories](https://github.com/Expatria-Technologies/Mods-Accessories)
- grblHAL [spindle plugins](https://github.com/grblHAL/Plugins_spindle) (`vfd/h100.c` register use)
- StepperOnline: [CL57Y V2.0 manual](https://files.omc-stepperonline.com/CL57Y_V2.0_pulse_stepper_driver_manual_V1.0.pdf) · [23HS40-5004D-E1000](https://files.omc-stepperonline.com/23HS40-5004D-E1000_Full_Datasheet.pdf) · [CE2-M2-20](https://files.omc-stepperonline.com/CE2-M2-20_Full_Datasheet.pdf)
- Mean Well: [NDR-480](https://www.meanwell.com/Upload/PDF/NDR-480/NDR-480-SPEC.PDF) · [SDR-120](https://www.meanwellaustralia.com.au/sites/default/files/2025-07/MEAN%20WELL%20SDR-120%20DATA%20SHEET.pdf) · [MDR-60](https://www.meanwell.com/Upload/PDF/MDR-60/MDR-60-SPEC.PDF) · [McMaster 3718N152](https://www.mcmaster.com/3718N152/) · [DDR-60](https://www.meanwell.com/Upload/PDF/DDR-60/DDR-60-SPEC.PDF) · [HDR-60](https://www.meanwell.com/Upload/PDF/HDR-60/HDR-60-SPEC.PDF) · [MDR-40](https://www.meanwell.com/Upload/PDF/MDR-40/MDR-40-SPEC.PDF) · [WDR-60](https://www.meanwell.com/Upload/PDF/WDR-60/WDR-60-SPEC.PDF) · [NDR-120](https://old.csi.pl/wp-content/uploads/2021/03/NDR-120.pdf)
- AutomationDirect: [HMC-18B30-11-DS](https://www.automationdirect.com/adc/shopping/catalog/motor_controls/iec_magnetic_contactors/iec_contactors/hmc-18b30-11-ds) · [IronHorse HMC spec](https://cdn.automationdirect.com/static/specs/ironhorsehmcandhtor.pdf)
- Adafruit 16 mm illuminated pushbuttons, momentary: [white 1479](https://www.adafruit.com/product/1479) · [green 1440](https://www.adafruit.com/product/1440) · [yellow 1441](https://www.adafruit.com/product/1441) · [blue 1477](https://www.adafruit.com/product/1477)
- [Murrelektronik 52003 datasheet](https://www.mouser.lt/datasheet/3/5927/1/52003_Product_PDF_en.pdf)
- [McMaster 7641K51 modular DIN terminal block](https://www.mcmaster.com/7641K51/) (TE Connectivity, 6 mm, choose-a-colour) · [Konnect-It fuse terminals spec](https://cdn.automationdirect.com/static/specs/konnectfuse.pdf)
- [Schurter TA35](https://www.schurter.com/en/datasheet/TA35_Rocker_2Pole) · [Neutrik powerCON TRUE1 (RS)](https://au.rs-online.com/web/p/industrial-power-connectors/2843431) · [Delta 20DRGS5](https://www.digikey.com/en/products/detail/delta-electronics/20DRGS5/2560387)
- [TeamFDM: Voron Cascade CNC](https://teamfdm.com/forums/topic/3556-voron-cascade-cnc) · [TeamFDM: Scylla on Milo (0–10 V scaling gotcha, Modbus preferred)](https://www.teamfdm.com/forums/topic/5392-bigtreetech-scylla-v1-firmware-installation/)
# Changelog
One line per change. The entries in full, up to 2026-11-16, are in [[Voron Cascade Electronics Wiring History]].
## 2026-11-08
- Created from a research pass over the Cascade repo and manual, the UEB wiring reference and the Flexi-HAL and remora-flexi-hal sources; three scripted drawings.
- Rev B: IronHorse 24 VDC contactor and SDR-120-24.
- Rev C: hardware latch K3 and the door switches in the KM1 coil chain.
## 2026-11-09
- Rev D: reconciled with the hardware in hand ([[Electronics]]): CL57Y-V20 drivers, NDR-480-48, Delta line filter. Note moved into the vault.
- Rev E, then Rev F: the 5 V supply (DDR-60G-5, then the MDR-60-5).
## 2026-11-10
- Rev G: Murrelektronik 52003 relays for K2 and K3.
- Rev H: K4 and the Y1 air-blast valve on the Mist output.
- Rev I: 22 mm GCX buttons and the GCX1131 E-stop; settings moved out to [[Voron Cascade Electrical Configuration]].
- Rev J: XT3 as a terminal strip with a block table; K5 added as the door relay; the ladder is ten rungs.
- Rev K: McMaster 7641K51 blocks and the colour scheme; Layout H's fit test folded in; the NDR's two output pairs; grounding block and bonding plan.
## 2026-11-11
- Rev L: operator controls redone. No POWER OFF, 16 mm buttons, CYCLE START and AIR added; [[#Operator controls]] section.
## 2026-11-12
- Rev L correction to the AIR button's HAL.
- [[#Wire numbers and labels]] added.
- Independent review of Rev L received: hold notice added, documentation errors corrected.
- Panel wire re-specified to the MTW on hand, nothing thinner than 20 AWG.
- Review S3 decided: access after a stop is a written rule.
- **Rev M**: the review's fixes (K2 follows the E-stop latch, the valve's feed through KM1's aux, status on the NC aux, 12 AWG bonding) and its accepted limits.
- PE group linked by wire (EL02).
## 2026-11-13
- Rear rail cut to 119 mm: fifteen blocks, second grounding block.
- Layout I: lower-rail holes re-spaced, marking jig added, relays in K2 K3 K4 K5 order.
- Review EL11 and EL08 decided: no DC branch fuses; F1 and F2 stay.
- VFD lowered 5 mm.
- Review documentation fixes (D2, D3, HW-07, HW-08, SW-10, SW-12).
- Lower-rail grounding block decided, drivers at 31 mm pitch.
- Rev M HAL run in the simulator. Un-homing on loss of drive power and the SPI link change approved and added.
## 2026-11-14
- FlexiHAL checked on the bench (A7): Aux pull-ups fitted, to be removed; terminal names and commons confirmed, so W24 is six cores.
- **Rev N**, for the second independent review.
- H100 moved to the lower rail on a printed DIN mount.
- Second review: three HAL changes (the link stop, KM1 dropping out trips the latch, reset refused while KM1 reads "in") and corrected statements.
- 48 V −V bond accepted at 18 AWG.
- VFD nameplate read: `H100-1.5C2-1B`, the 110 V unit.
- The SPI link follows the E-stop latch.
## 2026-11-15
- Third review received: the accepted limit written into rung 2, corrections made.
- **The door acts through LinuxCNC only**: KM1 A2 moves to K5 A2.
- **Rev O.**
- Rear-rail PE group: one grounding block, at block 11.
- Layout J, in its own note ([[Voron Cascade Electronics Layout]]).
- Door change: one missed line in the panel-wire paragraph corrected.
## 2026-11-16
- The last three entries of 2026-11-15 reached the vault today, written with Erik's approval over an edit of his from the evening of 2026-11-15 that Claude's session could not read. Whatever he changed then is not in this text.
- Decisions sorted newest to oldest, at Erik's request.
- Condensed, at Erik's request (164 KB to about 121 KB). No design change; the wiring stays at Rev O.
- Moved to [[Voron Cascade Electronics Wiring History]]: the Decisions and the Changelog in full as they stood, and the completed TODO items. Here, eleven decisions (reversed, replaced, or only naming a revision letter) are cut to a few lines each and the changelog to one line per change.
- Replaced by a summary and a link: the Configuration section ([[Voron Cascade Electrical Configuration]] has every setting), and the lower-rail jig and VFD-mount sections ([[Voron Cascade Electronics Layout]] has both, and took over the few details it lacked). Operator controls keeps the wiring and links out for behaviour and placement.
- The Design text says how things are, not how they came to be; the hold notice is a short list. The MDR's OVP and the NDR's input range moved to the rails section, the display's cables to W18, and the FlexiHAL terminal names stay under Configuration.
- The whole note as it stood before this is `media/cascade-wiring-note-2026-11-16-before-condensing.txt`.